• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 15:00来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (2)  
Put the FLT CONTROL A switch in the STDBY RUD position.

 (a)  Make sure the pressure line and the supply line do not have leaks.

 (3)  
Put the FLT CONTROL A switch in the OFF position.


 S 865-140
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 518 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-141
 WARNING:_______ MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF ALL CONTROL
 SURFACES BEFORE YOU SUPPLY HYDRAULIC POWER.  THE AILERONS,
 RUDDER, ELEVATORS, FLAPS, SLATS, SPOILERS, LANDING GEAR, AND
 THRUST REVERSERS CAN MOVE QUICKLY WHEN YOU SUPPLY HYDRAULIC
 POWER.  THIS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO

 EQUIPMENT.
 (4)  
Supply hydraulic pressure to system B (Ref 29-15-00/201). S 865-142

 (5)  
Set the flap control lever to the FLAP UP position. S 865-143

 (6)  
Remove hydraulic power from system B (Ref 29-15-00/201). S 865-144

 (7)  
Remove electrical power if it is not necessary (Ref 24-22-00/201).


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 519 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 HYDRAULIC SYSTEMS A, B, AND STANDBY - INSPECTION/CHECK
______________________________________________________
 1.  General_______
 A.  This procedure has one task. This task does a check of the hydraulic fluid.
 B.  The operational environment of the airplane hydraulic system can affect the service life of the hydraulic fluid. You make a decision to take a sample of the hydraulic fluid for analysis if you find that it is necessary from your service experience. Make sure that the fluid analysis results agree with the fluid specification limits shown in Table
 601. If the fluid properties are greater than the limits in Table 601, replace some quantity of fluid with new fluid until the fluid properties agree with the limits shown. You make a decision on the quantity of fluid to be replaced.
 C.  A polyethylene bottle or a glass bottle can be used to collect the hydraulic fluid.
 TASK 29-15-00-206-001
 2.  Hydraulic Fluid Check_____________________
 A.  General
 (1)  You must do the steps in this procedure to clean the bottles which will hold the fluid samples. If you do not do this, it is possible the fluid samples will not be correct. You must get one fluid sample from each reservoir.
 B.  Equipment
 (1)  
Polyethylene Bottle (capacity of 1-pint and a
 polyethylene screw cap with a seal) -Commercially Available


 (2)  
Glass Bottle (capacity of one pint and
 polyethylene screw cap with a seal) -Commercially Available


 (3)  
Clean Polyethylene Bags (to hold the bottles) -Commercially Available

 

 C.  Consumable Materials
 (1)  B00129 Isopropyl Alcohol, approximately 1-pint,
 put through a micronic filter membrane

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 02 Page 601 ú Nov 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 (2)  
E00011 Nitric Acid (20% by volume),
 approximately 1-pint


 (3)
G01061 Distilled Deionized Water, approximately 1-pint


 D. References
 (1)
AMM 12-12-00/301, Hydraulic Reservoir

 (2)
AMM 29-15-00/201, Hydraulic Systems A, B, and Standby


 E. Access
 (1)  Location Zones
 216 Left Main Wheel Well
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(80)