Make sure the No. 1 and No. 2 fuel tanks each have 250 gallons (1675 pounds/760 kilograms) of fuel in them.

 S 865-073

 (2)  
Supply electrical power (Ref 24-22-00/201).

 S 865-074

 (3)  
Close these circuit breakers:

 (a)  
P6-2 Panel
 1) ELEC HYD PUMP CONT SYS A
 2) ELEC HYD PUMP CONT SYS B
 3) ENG PUMP DEPRESS VALVE NO. 1
 4) ENG PUMP DEPRESS VALVE NO. 2
 5) HYDRAULIC SYSTEM PRESSURE IND SYS A
 6) HYDRAULIC SYSTEM PRESSURE IND SYS B
 7) HYDRAULIC SYSTEM OIL QTY IND SYS A
 8) HYDRAULIC SYSTEM OIL QTY IND SYS B


 (b)  
P6-3 Panel
 1) INDICATOR MASTER DIM BUS BAT
 2) INDICATOR MASTER DIM BUS NO. 1 DC
 3) INDICATOR MASTER DIM BUS NO. 2 DC
 4) INDICATOR MASTER DIM BUS SECT 1
 5) INDICATOR MASTER DIM BUS SECT 2
 6) INDICATOR MASTER DIM BUS SECT 3
 7) INDICATOR MASTER DIM BUS SECT 4
 8) INDICATOR MASTER DIM BUS SECT 5
 9) INDICATOR MASTER DIM BUS SECT 6

 

 

 S 865-075
 (4)  Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  P6-2 Panel
 1) PTU/LG BYP V CONT 1
 2) PTU/LG BYP V CONT 2

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 509 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 (b)  
P6-11 Panel
 1) STBY HYD PUMP NORMAL


 (c)  
P6-12 Panel
 1) STBY HYD PUMP ALTERNATE

 

 S 215-076
 (5)  
Make sure the ENG 1, ENG 2, ELEC 1, and ELEC 2 switches for the HYD PUMPS (on the P5 panel) are in the OFF position.

 S 015-077

 (6)  
Open the fan cowl panels for the applicable engine (Ref 71-11-02/201) (the left engine for system A, the right engine for system B).

 S 485-078

 (7)  
Disconnect the pressure and the supply lines from the engine-driven pump (EDP).

 (a)  
Connect the pressure line of the hydraulic service cart to the pressure line you disconnected from the EDP.

 (b)  
Connect the return line of the hydraulic service cart to the supply line you disconnected from the EDP.

 


 S 215-079
 (8)  
Make sure the supply shutoff valve for the EDP is open.

 S 215-081

 (9)  
Make sure the applicable HYD QTY gage (on the P3 panel) shows between RFL and F.

 S 215-080

 (10)
 Make sure the pressure in the applicable hydraulic system is zero.


 E. Procedure
 S 215-082
 (1)  Make sure the two LOW PRESSURE lights for the applicable HYD PUMPS are on.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 510 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 (2)  S 735-083Use the hydraulic service cart to slowly pressurize the hydraulic system to 3000 psi. (a) Make sure the applicable LOW PRESSURE light (ENG 1 or ENG 2) goes out when the pressure is between 1200 and 1600 psig. (b) Make sure the applicable HYD SYS PRESS indicator shows between 2900-3200 psig.
 (3)  S 735-084Slowly decrease the hydraulic pressure. (a) Make sure the applicable LOW PRESSURE light (ENG 1 or ENG 2) comes on when the pressure is between 1500 and 1100 psig.
 (4)  S 865-085Release all the pressure from the hydraulic system.
 (5)  S 085-086Disconnect the hydraulic service cart from the airplane.
 (6)  S 435-087Connect the pressure line and the supply line to the EDP.
 (7)  S 735-088Put the applicable HYD PUMPS ELEC 2 (for the A hydraulic system) or HYD PUMPS ELEC 1 (for the B hydraulic system) switch in the ON position. (a) Make sure the applicable LOW PRESSURE light (ELEC 1 or ELEC 2) goes out when the pressure is between 1100 and 1600 psig (use the HYD SYS PRESS indicator). (b) Make sure the pressure becomes stable between 2800-3200 psig.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(76)