C. Procedure
S 864-013
(1)
Release pressure from the hydraulic reservoirs (Ref 29-09-00/201).
S 864-014
(2)
Open the applicable circuit breakers and attach DO-NOT-CLOSE tags:
(a) P6-3 Circuit Breaker Panel 1) INDICATOR MASTER DIM BUS SEC 5 (system B) 2) INDICATOR MASTER DIM BUS SEC 6 (system A)
S 034-015
(3) Disconnect the supply line quick-disconnect to prevent high leakage of fluid.
NOTE: You can find the quick-disconnect for system A at the
____ reservoir and the quick-disconnect for system B at the EMDP.
S 034-016
(4)
Remove the electrical connector from the overheat switch.
(5)
Remove the overheat switch from the switch tee.
S 024-017
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-32-12
ALL ú ú 01 Page 401 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
SEE A
SYSTEM A RESERVOIR CASE DRAIN LINE SYSTEM B EMDP SYSTEM B RESERVOIR
FWD SYSTEM A EMDP
SUPPORT
BRACKET
A WASHER
OVERHEAT BULKHEAD NUT
SWITCH
SEE B TO THE HEAT
EXCHANGER AND
THE RESERVOIR
CASE DRAIN
O-RING LINE
OVERHEAT
SWITCH
ELECTRICAL
CONNECTOR
OVERHEAT SWITCH FOR SYSTEM A (SYSTEM B IS OPPOSITE)
B
EMDP Hydraulic Fluid Overheat Switch Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-32-12
ALL ú ú 01 Page 402 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 034-018
(6)
Discard the O-ring.
S 434-019
(7)
Install a cover on the open port of the tee fitting.
TASK 29-32-12-404-002
3. Hydraulic Fluid Overheat Warning Switch Installation (Fig. 401)____________________________________________________
A. Consumable Materials
(1)
D00567 Skydrol Assembly Lube - MCS 352
(2)
D00568 Fluid - Hydraulic, BMS 3-11
B. References
(1) 24-22-00/201, Manual Control
C. Access
(1) Location Zone
216 Main Wheel Well, LH
217 Main Wheel Well, RH
D. Procedure
S 644-003
(1)
Apply assembly lube or hydraulic fluid to the O-rings and the fittings threads.
S 424-004
(2)
Install the O-ring and the overheat switch in the open port of the tee fitting.
(3)
Install a lockwire.
(4)
Connect the electrical connector to the overheat switch.
S 434-005
S 434-006
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-32-12
ALL ú ú 01 Page 403 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 864-007
(5) Remove the DO-NOT-CLOSE tags and close the applicable circuit breakers:
(a) P6-3 Circuit Breaker Panel
1) INDICATOR MASTER DIM BUS SEC 5 (system B)
2) INDICATOR MASTER DIM BUS SEC 6 (system A)
S 434-020
CAUTION: MAKE SURE THE DISCONNECT POPPET IS STRAIGHT BEFORE YOU INSTALL
_______ THE HOSE HALF OF THE SELF-SEAL DISCONNECT. IF TOO MUCH TORQUE IS NECESSARY TO DO THE INSTALLATION, DISCONNECT THE SELF-SEAL DISCONNECT AND AGAIN MAKE SURE THE POPPET IS STRAIGHT. AFTER THE INSTALLATION, MAKE SURE THE INDICATOR PINS EXTEND A MINIMUM OF 0.06 INCH. IF THE INDICATOR PINS ARE NOT CORRECTLY EXTENDED, FLUID FLOW WILL BE DECREASED OR STOPPED. THIS CAN CAUSE DAMAGE TO THE RESERVOIR OR THE PUMP.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(155)