• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 15:00来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 S 865-005
 (5)  Open these circuit breakers and attach DO-NOT-CLOSE tags: (a) P6-2 Panel 1) PTU/LG BYP V CONT 1 2) PTU/LG BYP V CONT 2 (b) P6-11 Panel 1) STBY HYD PUMP NORMAL (c) P6-12 Panel 1) STBY HYD PUMP ALTERNATE
 S 865-006
 (6)  Make sure the supply shutoff valves for the engine-driven pump (EDP) are open.
 S 615-007
 (7)  Fill the hydraulic reservoirs (Ref 12-12-00/301), if they do not have sufficient hydraulic fluid in them.
 S 865-008
 (8)  Pressurize the hydraulic reservoirs (Ref 29-09-00/201), if they are not pressurized.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 502 ú Jul 15/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 D. Procedure
 S 215-009
 (1)  Make sure the four LOW PRESSURE lights for the HYD PUMPS (on the P5 panel) are on.
 S 715-010
 WARNING: MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF ALL CONTROL
_______ SURFACES BEFORE YOU SUPPLY HYDRAULIC POWER. THE AILERONS, RUDDER, ELEVATORS, FLAPS, SLATS, SPOILERS, LANDING GEAR, AND THRUST REVERSERS CAN MOVE QUICKLY WHEN YOU SUPPLY HYDRAULIC POWER. THIS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (2)  Put the HYD PUMPS A ELEC 2 switch (to do a test of system A) or the HYD PUMPS B ELEC 1 switch (to do a test of system B) in the ON position.
 (a)  
Make sure the pressure for the applicable hydraulic system becomes stable between 2800 and 3200 psig.

 (b)  
Make sure the applicable LOW PRESSURE light goes out.


 S 715-013
 (3)  Put the switch in the OFF position.
 (a)  Operate the rudder until the hydraulic pressure is zero. 1) Make sure the LOW PRESSURE light comes on.
 S 715-014
 (4)  
Put the HYD PUMPS A ENG 1 switch (to do a test of system A) or the HYD PUMPS B ENG 2 switch (to do a test of system B) in the ON position.

 S 985-016

 (5)  
Motor or operate the applicable engine (Ref 71-00-00/201).

 (a)  
Make sure the applicable LOW PRESSURE light goes out.

 (b)  
With the engine at idle speed or faster, make sure the pressure in the applicable hydraulic system is 2900 - 3200 psig.

 


 S 715-017
 (6)  Put the switch in the OFF position.
 (a)  Operate the rudder until the hydraulic pressure is zero. 1) Make sure the LOW PRESSURE light comes on.
 S 985-018
 (7)  Stop the engine (Ref 71-00-00/201).
 E. Put the Airplane Back to Its Usual Condition
 S 865-019
 (1) Remove electrical power if it is not necessary (Ref 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 503 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-020
 (2)  Remove the DO-NOT-CLOSE tags and close these circuit breakers:
 (a)  
P6-2 Panel
 1) PTU/LG BYP V CONT 1
 2) PTU/LG BYP V CONT 2


 (b)  
P6-11 Panel
 1) STBY HYD PUMP NORMAL


 (c)  
P6-12 Panel
 1) STBY HYD PUMP ALTERNATE

 

 TASK 29-15-00-715-021
 3.  Operational Test for the Standby Hydraulic System_________________________________________________
 A. References
 (1)  
24-22-00/201, Manual Control

 (2)  
29-15-00/201, Hydraulic Systems A, B, and Standby


 B. Access
 (1)  Location Zones
 101/102 Control Cabin
 216/217 Main Wheel Wells

 C. Prepare for the Test
 S 865-022
 (1)  
Supply electrical power (Ref 24-22-00/201).

 S 865-023

 (2)  
Close these circuit breakers:

 (a)  
P6-2 Panel 1) NOSE GEAR AIR/GND 2) FLIGHT CONTROL SHUTOFF VALVE STBY RUD 3) LANDING GEAR AIR/GND RELAY & LIGHTS

 (b)  
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(73)