737-300/400/500MAINTENANCE MANUAL
 (b)  The right APU GEN switch (if the APU is your supply of electrical power).
 S 715-007
 (7)  
Make sure the HYD PUMPS A ELEC 2 LOW PRESSURE light, on the P5 panel, comes on.

 S 865-008

 (8)  
Set the GEN 2 or the right APU GEN switch back to the ON position.

 S 715-009

 (9)
Make sure the HYD PUMPS A ELEC 2 LOW PRESSURE light goes off.

 S 865-010

 (10)
 Set the applicable switch, on the P5 panel, to the OFF position to remove electrical power from the system B pump:

 (a)  
The GEN 1 switch (if the engine is your supply of electrical power).

 (b)  
The left APU GEN switch (if the APU is your supply of electrical power).

 


 S 715-011
 (11)
 Make sure the HYD PUMPS B ELEC 1 LOW PRESSURE light, on the P5 panel, comes on.

 S 865-012

 (12)
 Set the GEN 1 or the left APU GEN switch back to the ON position.

 S 715-013

 (13)
 Make sure the HYD PUMPS B ELEC 1 LOW PRESSURE light goes out.


 D. Put the Airplane Back to Its Usual Condition
 S 865-015
 (1)  
Set the HYD PUMPS A ENG 1 and the HYD PUMPS B ENG 2 switches, on the P5 panel, to the ON position.

 S 865-016

 (2)  
Set the FLT CONTROL and the SPOILER systems A and B switches, on the P5 panel, to the ON position.

 S 865-017

 (3)  
Set the HYD PUMPS A ELEC 2 and the HYD PUMPS B ELEC 1 switches to the OFF position.

 (4)  
Remove electrical power if it is not necessary (Ref 24-22-00/201).


 S 865-018
 TASK 29-15-22-705-059
 3.  Ground Fault Protection System Test___________________________________
 A. Special Tools and Equipment
 (1)  Test Equipment, Ground Fault Protection, Hydraulic System F72917-19
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-22
 ú ú 02 Page 502 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 B.
C.
D.
E.
A
737-300/400/500MAINTENANCE MANUAL
References
 (1)
24-22-00/201, Manual ControlAccess

 (1)  
Location Zone 215 Main Wheel Well - left 216 Main Wheel Well - right

 (2)  
Access Panel P6-1 Circuit Breaker Panel P6-2 Circuit Breaker Panel


Prepare for the Test
 S 865-079
 (1)  
Supply electrical power (Ref 24-22-00/201).

 S 865-019

 (2)  
Open the applicable circuit breakers and attach DO-NOT-CLOSE tags:

 (a)  
P6-2 Panel
 1) ELEC HYD PUMP CONT SYS A
 2) ELEC HYD PUMP CONT SYS B


 (b)  
P6-11 Panel
 1) ELEC HYD PUMP SYS B


 (c)  
P6-12 Panel
 1) ELEC HYD PUMP SYS A

 

 

 S 035-020
 (3) Disconnect the electrical connector from the EMDP.System A Ground Fault Detector Test
 S 045-067
 WARNING: YOU MUST CONNECT THE GROUNDING CABLE FOR THE TEST EQUIPMENT TO
_______ THE AIRPLANE GROUND BEFORE YOU CONNECT THE ELECTRICAL CONNECTOR FOR THE PUMP TO THE TEST EQUIPMENT. INJURY TO PERSONS CAN OCCUR.
 (1)  
Disconnect the electrical connector from the system A EMDP.

 S 435-022

 (2)  
Connect the test equipment connector to the electrical connector for the EMDP.

 S 865-023

 (3)  
Remove the DO-NOT-CLOSE tags and close these circuit breakers:

 (a)  
P6-2 Panel
 1) ELEC HYD PUMP CONT SYS A


 (b)  
P6-12 Panel
 1) ELEC HYD PUMP SYS A

 

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-22
 ú ú 02 Page 503 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 (4)  S 865-024Set the HYD PUMPS A ELEC 2 switch, on the P5 panel, to the ON position.
 