B.
References
(1)
AMM 24-22-00/201, Manual Control
(2)
AMM 29-15-00/201, Hydraulic Systems A, B, and Standby
C.
Access
(1)
Location Zones
101/102 Control Cabin Left/Right
216/217 Left/Right Main Wheel Well
D.
Prepare for Test
S 865-027
(1)
Do this task: "Supply Electrical Power" (AMM 24-22-00/201).
S 865-002
(2)
Make sure these circuit breakers are closed:
(a)
P6-2 Circuit Breaker Panel 1) SHUTOFF VALVES - FLT CONT (two locations) 2) SHUTOFF VALVES - SPOILER 3) IND LIGHTS
S 865-003
(3)
Do this task to pressurize hydraulic systems A and B: "Hydraulic System A, B or Standby Pressurization" (AMM 29-15-00/201).
E.
Do the Test of the Flight Controls Hydraulic Modular Packages
S 725-022
(1)
Do the test of the modular package:
(a)
Set the two FLT CONTROL switches on the flight controls panel, P5-3, to the ON position.
(b)
Set the two SPOILER switches on the flight controls panel, P5-3, to the ON position.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-09-21
ALL ú ú 02 Page 501 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(c)
Make sure that the manual override levers of the two valve motors on the two modular packages are in POSITION 1.
(d)
Operate the aileron control wheel , control column, and rudder pedal sets to bleed the hydraulic system.
(e)
Make sure that there is no leakage of hydraulic fluid at the modular packages.
(f)
Set the two SPOILER switches to the OFF position.
(g)
Make sure that the manual override lever of the left valve motor on the two modular packages is in POSITION 2.
(h)
Turn the aileron control wheel.
(i)
Make sure that the spoilers do not operate.
(j)
Set the two FLT CONTROL switches to the OFF position.
(k)
Make sure that the manual override lever of the right valve motor on the two modular packages is in POSITION 2.
(l)
Make sure that the two LOW PRESSURE warning lights on the flight controls panel, P5-3, come on.
(m)
Set the two FLT CONTROLS switches to the ON position.
(n)
Make sure that the LOW PRESSURE warning lights go off.
(o)
Set the two SPOILER switches to the ON position.
S 865-026
(2)
Do this task to depressurize hydraulic systems A and B: "Hydraulic System A, B or Standby Depressurization" (AMM 29-15-00/201).
S 725-024
(3)
Make sure the LOW PRESSURE lights come on.
S 725-025
(4)
Make sure the master warning and caution lights and the flight controls warning light come on.
F.
Put the Airplane Back to Its Usual Condition
S 865-021
(1) Do this task if electrical power is not necessary: "Electrical Power Removal" (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-09-21
ALL ú ú 01 Page 502 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
FLIGHT CONTROLS SHUTOFF VALVE AND VALVE MOTOR -
_____________________________________________
REMOVAL/INSTALLATION
____________________
1. General_______
A. There are four tasks in this procedure. There is one task for the removal and one task for the installation of the flight control shutoff valve (the valve and the valve motor). There is also a task for the removal and a task for the installation of the motor of the flight controls shutoff valve.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 1(27)