(9) Clearing Data Fields Data fields on the MCDU can be cleared using the CLR key. Activating the CLR key when the scratchpad is empty results in CLR being displayed. This appears in columns 6 to 8 of the scratchpad. Then, activating the LS key adjacent to the data field results in clearing that data and the scratchpad line is cleared. If the data have a default or computer calculated value, the data revert to this value. If the default value is cleared, the clearing has no effect and there is no message displayed. To remove a CLR prompt from the scratchpad, the CLR key can be activated again once. Or any alphanumeric key can be activated erasing the CLR in the scratchpad and entering the alphanumeric. The computer must distinguish between the CLR key and C-L-R being entered into the scratchpad via alphanumeric keys. C-L-R does not enable the clearing function.
(10) MCDU Data Field Display Generally, a data is displayed on two lines:
-
the label line above the data line,
-
the data line next to the LSK.
On the data line there are five kinds of display:
-Cyan data if the data is already in the computer and the operator can modify it.
-Green data if the data is already in the computer but it cannot be modified by an operator entry.
-Cyan brackets (- -) if no value is defined and the operator can enter the data.
-Amber boxes ( ) if no value is defined. Then the data entry is mandatory for the correct functioning of the system. Or for the achievement of the function described on the page or on the label line.
-White dashes ( --- ) if the field is filled by the computer but not yet available. Due to lack of information or a computation has not yet been or a computation has no yet been achieved.
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page A18 1 1 Config-2 Aug 01/05 1 1 1CES 1 The entry format of data is described by the number of boxes or the place occupied by the brackets, or the spaces between brackets. On one data line, several data may be displayed and entered : the different fields are separated by a slash ('/'). Each field may be entered separately; it is identified by the number of slashes in front of the entered data: e.g.: EQ/SYS/LAB/SDI to modify the label, the operator has to enter into the scratchpad : '//label'.
(11)
Clearing Messages Any message that is displayed can be cleared by activating the CLR key. Messages are automatically cleared under the following conditions:
-
When data are entered into the scratchpad
-
When LS or MODE key is activated
-
When the reason is no longer valid.
(12)
Use of more than one MCDU at the same Time The FDIMU communicates with one MCDU only at the same time. If MCDU communication is requested from any of these MCDU's while communication is already active on another MCDU, the FDIMU responds with the message: "AIDS (TIMEOUT)". (Ref. Fig. 013)
**ON A/C 151-199, 201-210,
D. MCDU Functions and Rules
(Ref. Fig. 012A)
Some of the AIDS functions may be controlled via the MCDU.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 3(85)