AIDS - Parameter Call-Up (Label)
Figure 063
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B15 1 1 Config-2 Aug 01/05 1 1 1CES 1
2
_
3
_
4
_
The values of the selected parameters updates once per second. If the selected parameter not received or updated within one second the parameter is marked with > indication.
Label Port List Access:
-
Set AIDS on the MCDU MENU menu
-
Set LABEL on the AIDS main menu
-
Set PORT LIST on the AIDS Label Call-Up Control menu.
Display:
The Label Port list shows the connected FDIMU ARINC 429 inputs
with Port Number, connected System, Equipment Number and
System Number.
Define, Select, Store, Delete and Clear of Label Call-Up Contents Access:
-
Set AIDS on the MCDU MENU menu
-
Set LABEL on the AIDS main menu. Entry:
-Define/Select of Setup Name: Enter with the alphanumeric keys 5 character into the scratchpad and push the line select key (2L) below SETUP NAME indication. Does the entered Setup Name exist in the stored Label Menu Setups the content of this is now active. Otherwise a new Setup Name is defined.
-Store: Push the line key adjacent to STORE indication to save the Setup Name with the contents.
-Delete: Push the line key adjacent to DELETE indication to erase the Setup Name with the contents.
-Clear: Push the line key adjacent to CLEAR indication to clear all parameters in current (selected/active) Label Call-Up Setup.
Display:
The current Setup Name shows below the SETUP NAME indication
if one is selected or defined. The stored Label Menu Setups
shows below the STORED LABEL MENU SETUPS indication.
Print Record of an Online Parameter Trace This function allows to record the parameter from the current Label Call-Up Menu Setup on the printer. The printout starts immediately after selection. Access:
-
Set AIDS on the MCDU MENU menu.
-
Set LABEL on the AIDS main menu.
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B16 1 1 Config-2 Aug 01/05 1 1 1CES 1
Entry:
Enter with the alphanumeric keys the number of seconds (3
digits) into the scratchpad and push the line key adjacent to
START indication.
Result:
For the entered time the printer prints the values of the
current Label Call-Up Menu with a rate of 1 Hz.
5 Display of DFDRS Labels
_ For verification of correct FDIMU ARINC 717 input/output the DFDRS Label Call-Up menu is provided. Access:
-
Set AIDS on the MCDU MENU menu
-
Set LABEL on the AIDS main menu
-
Set DFDR/LABEL on the AIDS Label Call-Up Control menu.
Entry:
Enter with the alphanumeric keys DFDRS Word (3 digits) into
the scratchpad and push the line key adjacent to the WORD
indication.
Display/Result:
The SYNC WORDS SF#1, SF#2, SF#3 and SF#4 for DFDR and Playback
shows on the display.
6 Possible Scratchpad Messages
_
-----------------------------------------------------------------------------| Scratchpad Message | Reason | |------------------------|--------------------------------------------------| | ENTER PARAMETER NUMBER | - Default message at menu call-up | |------------------------|--------------------------------------------------| | NOT ALLOWED | - Undefined LSK or | | | - Invalid MCDU Mode Key or | | | - Up, Down, Left, Right Arrow Key | |------------------------|--------------------------------------------------| | INVALID ENTRY | - Equipment Identification (EQ) is not a valid | | | 3 character hex number or | | | - System Number (SYS) not within 1, 2, 3 or 4 or| | | - Label (LAB) is not a valid 3 character octal | | | number within 000 to 377 or | | | - SDI code is not within 00, 01, 10, 11, XX or | | | - Number of Databits is not a valid 2 digit | | | decimal number within 0 to 20 or | | | - At least one of the mandatory parameter number | | | parts EQ, SYS, LAB, SDI is missing and has not | | | been entered previously or | | | - Invalid delimeter character (/) or | | | - Any further undefined characters |
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B17 1 1 Config-2 Aug 01/05 1 1 1CES 1