R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 80 1 1 Config-1 May 01/05 1 1 1CES 1
MCDU - Return Function R Figure 013
R 1EFF : 001-049, 101-105, 1 31-36-00Page 81 1 1 Config-1 May 01/05 1 1 1CES 1R MCDU - Return Function R Figure 013A
R 1EFF : 051-099, 1 31-36-00Page 82 1 1 Config-1 May 01/05 1 1 1CES 1
MCDU - Display Print R Figure 014
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 83 1 1 Config-1 May 01/05 1 1 1CES 1R **ON A/C 001-049, 101-105,
E. MCDU Controlled DMU Function The AIDS main menu provide access to the following functions:
* Parameter Callup:
-
Parameter Label Call-Up
-
Parameter Alpha Call-Up
-
Parameter Menus
*
Load Status Display
*
List of Previous Reports
*
List of Stored Reports
*
Manual Report Request
*
Assignment of Remote Print
*
SAR/DAR Functionallity
-SAR Summary
-List of SAR stored Records
-SAR Manual Request
-
DAR PCM
-
DAR Run Control Switch
* DMU Programming
-
Report Inhibition
-
Report Limits
-
Report Internal Counters
-Statistic Counters
* DMU Programming
-
Report Inhibition
-
Report Limits
-
Report Internal Counters
-Statistic Counters
R **ON A/C 051-099,
R E. MCDU Controlled DMU Function
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 84 1 1 Config-1 May 01/05 1 1 1CES 1
R The AIDS main menu gives access to these functions:
R
R * Parameter Callup:
R - Parameter Label Call-Up
R - Parameter Alpha Call-Up
R - Parameter Menus
R
R * Load Status Display
R * List of Previous Reports
R * List of Stored Reports
R * Manual Report Request
R * Assignment of Remote Print
R * SAR/DAR Functionallity
R - SAR Summary
R - List of SAR stored Records
R - SAR Manual Request
R - DAR PCM
R - DAR Run Control Switch
R
R * DMU Programming
R - Report Inhibition
R - Report Limits
R - Report Internal Counters
R - Statistic Counters
R
R * DMU Programming
R - Report Inhibition
R - Report Limits
R - Report Internal Counters
R - Statistic Counters
R
R * Micro 3 (user programmable functions on the 3rd micro processor board)
R
R * PCMCIA
R - Disk Identification
R - Disk Directory
R - DAR Recording
R **ON A/C 001-049, 051-099, 101-105,
F. User Access Levels
All DMU functions, which can be manually activated by the user through
the MCDU are protected by a user access control mechanism based on a
password-mechanism. Two User Access Levels are defined as follows:
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 85 1 1 Config-1 May 01/05 1 1 1CES 1
----------------------------------------------------------------------
| Security Access User Identification | |--------------------------------------------------------------------| |No.| Code | Name: | Password | |---|-----------------------------------------------------|----------| | 1 | ANYBODY | Unidentified User | -------- | |---|-----------------------------------------------------|----------| | 2 | LINEMTCE | Line Maintenance | SFIMP | ----------------------------------------------------------------------
No password entry is required to enable the access to the 'Security User
No. 1' (ANYBODY) protected AIDS functions. For the 'Security User No. 2'
(LINEMTCE) protected AIDS functions an 8 character Security User Code
(Password) are necessary.
Individual Security Access Control is provided for:
-
Each MCDU Menu
-
Each AIDS Report
-
Each SAR Channel The contents of the Security MCDU Access Matrix represents the AI Standard Setup of the delivered DMU software.