 -----------------------------------------------------------------------------| Security User MCDU Function |Security | | |Access User | |-------------------------------------------------------------|-------------| | AIDS Main Menu | No Access | | - Manual DAR Start/Stop Control | Restrictions| |-------------------------------------------------------------|-------------| | Label Call-Up | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Alpha Call-Up | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Load Status | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Manual Report Request | ANYBODY (1) | | - List Selected Reports on MCDU screen | | | - Print Selected Report | | | - Send Selected Report (via ACARS) | | |-------------------------------------------------------------|-------------| | List of Stored Reports | ANYBODY (1) | | - List Selected Reports on MCDU screen | | | - Print Selected Report | | | - Send Selected Report (via ACARS) | | |-------------------------------------------------------------|-------------| | List of Previous Reports | ANYBODY (1) | |-------------------------------------------------------------|-------------| | SAR/DAR | ANYBODY (1) |
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 86 1 1 Config-1 May 01/05 1 1 1CES 1 -----------------------------------------------------------------------------| Security User MCDU Function |Security | | |Access User | |-------------------------------------------------------------|-------------| |-------------------------------------------------------------|-------------| | SAR Summary | ANYBODY (1) | |-------------------------------------------------------------|-------------| | List of SAR Stored Record | ANYBODY (1) | |-------------------------------------------------------------|-------------| | SAR Manual Request | ANYBODY (1) | |-------------------------------------------------------------|-------------| | DAR PCM | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Assignment of Print Button | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Programming | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Report Inhibit | LINEMTCE (2)| |-------------------------------------------------------------|-------------| | Report Limits | LINEMTCE (2)| | - Report Oil Table | | |-------------------------------------------------------------|-------------| | Report Int Counter | LINEMTCE (2)| |-------------------------------------------------------------|-------------| | Statistic Counters | LINEMTCE (2)| -----------------------------------------------------------------------------


It is possible to redefine the Security Access User assignment on the GSE by the use of the reconfiguration software. If a user has insufficient access priviliges for a menu, he is able to call-up the menu but not to initiate any functions or to modify any data. All generated reports and SAR files are displayed in the respective menus. If a user has insufficient access privilleges for specific reports or SAR files only the asterisks for initiation of report output is removed.
 (1) Parameter Call Up Menu The parameter call-up functions are a part of the DMU operational software. The operation of the alpha call-up function will depend on the availability of an alpha call-up table and associated EUC table.
 (a) Parameter Label Call-up
R **ON A/C 001-049, 101-105,
R (Ref. Fig. 015)
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 87 1 1 Config-1 May 01/05 1 1 1CES 1


 Parameter Label Call-Up R Figure 015
R 1EFF : 001-049, 101-105, 1 31-36-00Page 88 1 1 Config-1 May 01/05 1 1 1CES 1R **ON A/C 051-099,

 

R (Ref. Fig. 015A)

R **ON A/C 001-049, 051-099, 101-105,
 Each parameter transmitted on one of the up to 64 ARINC 429 connected data buses are selectable for display on the MCDU screen. The selection are made using EQ, source system, label and SDI. Additionally the number of data bits to be used for decimal representation are selectable. The parts of the parameter number are isolated with a slash '/'. The number of the data bits can be omitted. The default value is
 18. The displayed parameters are updated once per second. Up to 2 parameters are displayed on one page. 8 pages can be selected via slew up/slew down button, which leads to a maximum number of 16 parameters to be monitored simultaneously. Example : Parameter Call-Up with EQ and System Number EQ/SYS/LAB/SDI = 1A/2/156/01
 1 The procedure to select the Parameter Label Call-Up Menu is as
_
 follows:

 -
Set 'AIDS' on the MCDU Menu.

 -
Set 'PARAM' on the AIDS Main Menu.

 -
Set 'PARAM LABEL CALL-UP' on the AIDS Param Call-Up Menu.
 