 4. Procedure
_________
 **ON A/C 001-049, 051-099, 101-105,

 Subtask 31-36-00-740-056
 A. Enter the Parameter Label Call-up through MCDU.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the MCDU:  On the MCDU display:
 -
Push the MCDU MENU mode key. - The MCDU MENU page shows.

 -
Push the Line Select Key (LSK)  - The AIDS page shows.
 adjacent to < AIDS indication.


 -
Push the LSK adjacent to CALL-UP <  - The AIDS PARAM CALL-UP page shows. PARAM indication.

 -
Push the LSK adjacent to < PARAM  - The AIDS PAR LAB CALL-UP page shows. LABEL CALL-UP indication.


 1EFF : ALL 1 31-36-00Page 230 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
R R R  ACTION RESULT -------------------------------------------------------------------------------- Enter the Parameter Label Call-up - The Parameter Label Call-up shows on with the alphanumeric keys in the the bottom of the display format as follows: EQ/SYS/LAB/SDI (scratchpad). and optional /DATABITS (Ref. AMM 31-37-00-001).
 NOTE : It is important to enter the DATABITS value if it is other than the____ default. The decimal value calculation is based on its value. 
R R  - Push the LSK 1L or 4L to take over the Parameter Label Call-up.  - The Parameter Label call-up shows on the Data Field with all information.
 NOTE : Two Label Call-up parameters can____ be displayed at one time. 
R  - Push the MCDU MENU mode key.  - The MCDU MENU page shows.
 Subtask 31-36-00-740-057
 B. Enter the Parameter Alpha Call-up via MCDU.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the MCDU:  On the MCDU display:
 - Push the MCDU MENU mode key.  - The MCDU MENU page comes into view.
 - Push the line key adjacent to < AIDS indication. - The AIDS page comes into view.
 - Push the line key adjacent to CALL-UP < PARAM indication.  - The AIDS PARAM CALL-UP page comesinto view.
 - Push the line key adjacent to < PARAM ALPHA CALL-UP indication.  - The AIDS ALPHA CALL-UP page comesinto view.
 - Enter the correct Alpha Call-up Code with the alphanumeric keys (Ref. AMM 31-36-00-001). See at the Parameter Alpha Call-up List (Ref. AMM 31-37-00-001).  - The Parameter Alpha Call-up shows onthe bottom of the display(scratchpad).

R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 231 1 1 May 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-
Push the line key 2L, 3L, 4L or 5L  - The Parameter Alpha Call-up shows on Key to take over the Parameter the Data Field with all information. Alpha Call-up.

 -
Push the MCDU MENU mode key. - The MCDU MENU page comes into view.

 

R **ON A/C 106-149, 211-299, 301-399, 401-499,
 Subtask 31-36-00-740-056-B
 A. Enter the Parameter Label Call-Up through MCDU.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the MCDU:
-
Push the MCDU MENU mode key.

-
Push the Line Select Key (LSK) adjacent to the < AIDS indication.

 -
Push the LSK adjacent to the < PARAMETER CALL UP LABEL indication.

 -
Push the LSK adjacent to the < LABEL MENU DISPLAY indication.


 -Enter the Parameter Label Call-Up with the alphanumeric keys in the format as follows: EQ/SYS/LAB/SDI and optional /DATABITS (Ref. AMM 31-37-00-001).
On the MCDU display:
-
The MCDU MENU page shows.

-
The AIDS page shows.

-
The AIDS:LABEL CALL-UP CTRL pageshows.

-
The AIDS:LABEL CALL-UP page shows.

-
The Parameter Label Call-Up shows onthe bottom of the display(scratchpad).


 NOTE : It is important to enter the DATABITS value if it is other than the
____ default. The decimal value calculation is based on its value.
 -Push the LSK 1L or 4L to take over  - The Parameter Label Call-Up shows on the Parameter Label Call-Up. the Data Field with all information.
R 1EFF : 001-049, 051-099, 101-149, 211-299, 1 31-36-00Page 232 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 3(129)