• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-25 12:14来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 get access to the 'Security User 1' functions (lowest access rights). The
 'Security User 1' functions are enabled automatically after power-up of
 the FDIMU.
 No password entry is necessary to branch into the sub-menus, to print
 MCDU screens and to enter report and SAR/DAR channel numbers for the
 purpose of menu selection.
 Three user access levels are defined as follows: 

R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B42 1 1 Config-2 Aug 01/05 1 1 1CES 1


 AIDS - DAR Recording
 Figure 075

R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B43 1 1 Config-2 Aug 01/05 1 1 1CES 1


 ----------------------------------------------------------------------
| Security Access User Identification | |--------------------------------------------------------------------| |No.| Code | Name: | Password | |---|-----------------------------------------------------|----------| | 1 | ANYBODY | Unidentified User | XXXX | |---|-----------------------------------------------------|----------| | 2 | LINEMTCE | Line Maintenance | LINE | |---------------------------------------------------------|----------| | 3 | ENGINEER | AIDS Engineer | ENGI | ----------------------------------------------------------------------
The following table defines for each user function of the FDIMU the type of security user, for which these function are enabled.
 -----------------------------------------------------------------------------| Security User MCDU Function |Security | | |Access User | |-------------------------------------------------------------|-------------| | Data Recording | ANYBODY (1) | | Run Control | | |-------------------------------------------------------------|-------------| | Label Call-Up | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Alpha Call-Up | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Manual Report Request | ANYBODY (1) | | | | | Print Report | | | Send Report | | |-------------------------------------------------------------|-------------| | List of stored Reports | ANYBODY (1) | | Print stored Reports | | | Send stored Reports | | | Dump stored Reports | | |-------------------------------------------------------------|-------------| | Manual Request of SAR Recording | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Manual Dump of SAR Channels | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Manual Dump of SAR Files | ANYBODY (1) | |-------------------------------------------------------------|-------------| | Enter Password |NO PROTECTION| |-------------------------------------------------------------|-------------| | Enter/Modify Statistic Counter Values | LINEMTCE (2)| | | ENGINEER (3)|| |-------------------------------------------------------------|-------------|
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B44 1 1 Config-2 Aug 01/05 1 1 1CES 1 -----------------------------------------------------------------------------


| Security User MCDU Function |Security |
 | |Access User |
 |-------------------------------------------------------------|-------------|
 | Report Inhibit | LINEMTCE (2)|
 | | ENGINEER (3)|
 |-------------------------------------------------------------|-------------|
 | Report Constants | |
 | Reprogramming | |
 | | |
 | Modify Values of Customer | ENGINEER (3)|
 | Programmable Constants of | |
 | the selected Report | |
 |-------------------------------------------------------------|-------------|
 | Report Counter /Logic Reset | LINEMTCE (2)|
 | | ENGINEER (3)||
 -----------------------------------------------------------------------------
It is possible to redefine the Security-Access User assignment on the GSE by the use of the reconfiguration software.

R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
 8. Test BITE
_________

R **ON A/C 106-149, 211-299, 301-399, 401-499,
 A. General The FDIMU contains Built-In Test Equipments (BITE) in according to ARINC 604 regulations. One is for the DFDRS part and a second is for the AIDS part. The BITE's are able to detect at least 95% of the possible failures in the FDIMU. The detected failures are devided in system internal faults (FDIMU, DAR) and external faults (connected systems). If a failure is detected the BITE stores the failure messages in the FDIMU BITE memory and sends these continuously to the CFDS through the ARINC 429 output bus. The failures can be called up through the CFDS on the MCDU display.
 B. Test
 (1) POR BITE After each Power-On-Reset (POR) the FDIMU performs a POR Built-In Test (BITE). For a POR the electrical power must be interrupt greater than 200 msec. In case of the FDIMU does not operate in the correct mode you can perform a manual Power-up initialization through open the circuit breaker 5TV for 5 seconds. The POR BITE will be performed
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 3(114)