AIDS - Report Constants Reprogramming
Figure 069
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B29 1 1 Config-2 Aug 01/05 1 1 1CES 1
-----------------------------------------------------------------------------
| Scratchpad Message | Reason |
|------------------------|--------------------------------------------------|
| ENTER/INCR REPORT | - Default message at menu call-up |
| NUMBER | |
|------------------------|--------------------------------------------------|
| NOT ALLOWED | - Undefined LSK or |
| | - Invalid MCDU Mode Key or |
| | - Left, Right - Arrow Key |
|------------------------|--------------------------------------------------|
| INVALID ENTRY | - LSK-1L: Entered character do not represent a |
| | a valid integer number |
| | - LSK-2L...5L: Entered characters do not |
| | represent valid decimal number |
|------------------------|--------------------------------------------------|
| OUT OF RANGE | - LSK-2L...5L: Entered number fits not into the |
| | valid constant value range |
|------------------------|--------------------------------------------------|
| UNKNOWN REPORT | - LSK-1L: Invalid report number |
| NUMBER | |
-----------------------------------------------------------------------------
(g) Report Counter / Logic Reset
(Ref. Fig. 070)
This submenu allows to reset or change the report counter.
Access:
- Set AIDS on the MCDU main menu
- Set REPROGRAMMING on the AIDS menu
- Enter LINEMTCE or ENGINEER level user access password
- Set RESET on the AIDS SPECIAL FUNC/REPROG menu
- Use the scroll arrows to get access to the next pages.
Reset/Change:
R
R - To reset the report counter (reset to the GSE programmed value)
R push the CLR mode key and push the line select key adjacent to
the associated report.
R
R - To change the report counter number enter the new value into
R the scratchpad and push the line key adjacent to the associated
report.
Display:
On the multiple AIDS REPORT RESET pages show the reports with the
counter data as follows:
- Report number and Report name (upper line)
- Report Counter Name with current counter state (lower line)
- Name of the counter re-initialization constant with the GSE
programmed value (lower line in brackets).
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B30 1 1 Config-2 Aug 01/05 1 1 1CES 1
AIDS - Report Counter / Logic Reset
Figure 070
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page B31 1 1 Config-2 Aug 01/05 1 1 1CES 1
If a counter is not changeable (no or wrong user access code) the
current counter value shows in green color.
(6) List of Stored Reports
(Ref. Fig. 071)
As long as a report is stored in the report storage the respective
report title and report number is listed. These reports are available
for print out or for download or for downlink through ACARS.
Access:
- Set AIDS on the MCDU main menu
- Set STORED REPORTS on the AIDS menu
- Use the scroll arrows to get access to the next pages.
Selection:
- Push the NEXT PAGE key to change the output function.
- Enter the Report number into the scratchpad and push the line
select key 1L to find the related Report. To show all stored
Reports enter XX into the scratchpad.
- To clear pending output requests push the line select key adjacent
to the asterix behind the displayed report (user access key
necessary).
Display:
Above the listed reports the output selection shows. The current
selected output device is on the left side and the alternate devices
shows in the brackets.
The listed stored reports contain:
- Flight leg number of report generation
- Trigger code, trigger logic, which triggered the report
- UTC of the report generation
- Date of the report generation
- Output status according the 'Immediate Output Rule'
- Report number and
- Report name.
If no reports are stored the message NO REPORTS shows.
Possible Output Status:
R - EOF : Waiting for End-Of-Flight