-------------------------------------------------------------------------------DMU Discrete Inputs - Table 5
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 23 1 1 Config-1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
| CONNECTOR | PIN | TYPE | DESCRIPTION | OUT|
| | | | | NO |
|-----------------------------------------------------------------------------|
| TP | 15D | ABD 0048 | DMU FAIL | 01 |
| | | | | |
| MP | 13A | REF SPEC | DAR RUN CONTROL H : | |
| | | | > DMU INTERNAL | 06 |
| MP | 13B | REF SPEC | DAR RUN CONTROL L : LINK | |
| | | | : | |
| MP | 13F | - | DAR SPEED CTRL COMMON (0V OR +5V) | |
| | | | : | |
| TP | 13J | REF SPEC | DAR SPEED SELECT X 2 | 02 |
| | | | | |
| TP | 13K | REF SPEC | DAR SPEED SELECT X 4 | 03 |
| | | | | |
| TP | 14J | REF SPEC | DAR SPEED SELECT X 6 | 04 |
| | | | | |
| TP | 14K | REF SPEC | DAR SPEED SELECT X 8 | 05 |
-------------------------------------------------------------------------------DMU Discrete Outputs - Table 6
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 24 1 1 Config-1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
| CONNECTOR | PIN | DESCRIPTION |
|-----------------------------------------------------------------------------|
| BP | 1 | 115V AC H |
| | | |
| BP | 7 | 115V AC L |
| | | |
| TP | 15H | DIGITAL GROUND |
| | | |
| TP | 15J | DIGITAL GROUND |
| | | |
| TP | 15K | CASE GROUND |
| | | |
| MP | 15H | DIGITAL GROUND |
| | | |
| MP | 15J | DIGITAL GROUND |
| | | |
| MP | 15K | CASE GROUND |
-------------------------------------------------------------------------------DMU Power Supply and Ground Pins - Table 7
R 1EFF : 001-049, 051-099, 101-105, 1 31-36-00Page 25 1 1 Config-1 May 01/05 1 1 1CES 1
------------------------------------------| PIN | CONTACT FUNCTION |
|-----|----------------------------------|
| 1 | 115 V / 400 HZ |
| 2 | 115 V / 400 HZ |
| 3 | RS422 IN A |
| 4 | RS422 IN B |
| 5 | RESERVED |
| 6 | PDL enable |
| 7 | PDL Data in A |
| 8 | PDL Data in B |
| 9 | TXD RS232 Option CPU 3 |
| 10 | RS 422 OUT A |
| 11 | RS 422 OUt B |
| 12 | TEST 1 (ARINC 429) A Port 49 |
| 13 | TEST 1 (ARINC 429) B Port 49 |
| 14 | RESERVED |
| 15 | V Battery 1 |
| 16 | RESERVED |
| 17 | RESERVED |
| 18 | RESERVED |
| 19 | RS 422 Switch |
| 20 | Ground ((Mechanic) |
| 21 | TXD RS 422 CPU 1 |
| 22 | RXD RS 232 CPU 1 |
| 23 | TXD RS 422 CPU 2 |
| 24 | RXD RS 232 CPU 2 |
| 25 | Ground (Electric) |
| 26 | PDL Data Out A |
| 27 | PDL Data Out B |
| 28 | RXD RS 232 Option CPU 3 |
| 29 | Ground (Electric) |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn