D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
B. Location Zones
Zone Area
211 Flight Compartment - Left
212 Flight Compartment - Right
C. Shaker Installation
SUBTASK 27-32-31-420-001
(1) Attach the shaker [1] to the strap on the control column with the bolts [5], nuts [4], shims [3], and
spacers [2].
SUBTASK 27-32-31-420-002
(2) Tighten the bolts to 20-25 pound-inches.
SUBTASK 27-32-31-420-003
(3) Add or remove shims as necessary between the shaker [1] and strap to get a snug fit.
SUBTASK 27-32-31-860-002
(4) Remove the safety tags and close these circuit breakers:
CAPT Electrical System Panel, P18-2
Row Col Number Name
E 4 C01392 STICK SHAKER LEFT
F/O Electrical System Panel, P6-1
Row Col Number Name
B 6 C01393 STICK SHAKER RIGHT
D. Shaker Installation Test
SUBTASK 27-32-31-710-001
(1) Do a post-installation check of the shaker.
(a) Push and hold the STALL WARNING TEST NO. 1 switch (for the captain’s shaker) or NO. 2
switch (for the first officer’s shaker) on the P5 panel.
(b) Make sure the applicable shaker operates.
(c) Release the switch.
(d) Make sure that the shaker [1] stops.
------------------------- END OF TASK ---------------------------
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-32-31
Page 402
Jun 10/2005
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
Control Column Shaker Installation
Figure 401/27-32-31-990-801
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-32-31
Page 403
Oct 10/2003
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
STALL MANAGEMENT YAW DAMPER (SMYD) - REMOVAL/INSTALLATION
1. General
A. This procedure has these tasks:
(1) Removal of the stall management yaw damper.
(2) Installation of the stall management yaw damper.
TASK 27-32-42-000-801
2. Stall Management Yaw Damper (SMYD) Removal
(Figure 401)
A. References
Reference Title
20-10-07-000-801 E/E Box Removal (P/B 201)
20-40-12-000-802 ESDS Handling for Metal Encased Unit Removal (P/B 201)
20-40-12-000-803 Conductive Dust Cap and Connector Cover Installation (P/B 201)
B. Location Zones
Zone Area
118 Electrical and Electronics Compartment - Right
C. Access Panels
Number Name/Location
117A Electronic Equipment Access Door
D. Prepare for the Removal
SUBTASK 27-32-42-860-001
(1) If you will remove the number 1 SMYD, do this step:
Open these circuit breakers and install safety tags:
CAPT Electrical System Panel, P18-2
Row Col Number Name
E 4 C01392 STICK SHAKER LEFT
E 5 C01204 SMYD-1 CMPTR DC
E 6 C01205 SMYD-1 SNSR EXC AC
SUBTASK 27-32-42-860-002
(2) If you will remove the number 2 SMYD, do this step:
Open these circuit breakers and install safety tags:
F/O Electrical System Panel, P6-1
Row Col Number Name
B 4 C01207 SMYD-2 SNSR EXC AC
B 5 C01206 SMYD-2 CMPTR DC
B 6 C01393 STICK SHAKER RIGHT
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-32-42
Page 401
Jun 10/2005
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
SUBTASK 27-32-42-010-001
(3) Open this access panel:
Number Name/Location
117A Electronic Equipment Access Door
E. SMYD Removal
SUBTASK 27-32-42-910-001
CAUTION: DO NOT TOUCH THE SMYD BEFORE YOU DO THE PROCEDURE FOR DEVICES THAT
ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE
CAN CAUSE DAMAGE TO THE SMYD.
(1) Do the necessary steps to protect the SMYD from electrostatic discharge. To do this, do this task:
ESDS Handling for Metal Encased Unit Removal, TASK 20-40-12-000-802.
SUBTASK 27-32-42-020-001
(2) Loosen the SMYD hold down knob.
NOTE: Refer to (E/E Box Removal, TASK 20-10-07-000-801) for further details on the E/E box
removal.
SUBTASK 27-32-42-020-002
(3) Carefully move the SYMD [1] out from the tray and remove the SYMD [1].
NOTE: Move the front of the SMYD from side to side approximately 1/8 inch to help disconnect
the SMYD from the electrical connector.
SUBTASK 27-32-42-420-001
CAUTION: DO NOT TOUCH THE CONDUCTOR PINS OR OTHER CONDUCTORS ON THE SMYD. IF
YOU TOUCH THESE CONDUCTORS, ELECTROSTATIC DISCHARGE CAN CAUSE
DAMAGE TO THE SMYD.
(4) Install protective covers on the SMYD connectors. To do this, do this task: Conductive Dust Cap
and Connector Cover Installation, TASK 20-40-12-000-803.
 