• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-06 23:21来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (4)  S 745-102Push the LSK adjacent to <OTHER FUNCTIONS from the CMC MENU page 2/2 on the CDU.
 (5)  S 745-103Push the LSK adjacent to <INPUT MONITORING from the OTHER FUNCTIONS MENU page on the CDU.
 (6)  S 745-104Use the alphanumeric keys on the CDU to put "E/53/350/00" into the scratchpad.
 (7)  S 745-105Push the LSK 1L to move the data into the correct position.
 (8)  S 745-106Make sure that bits 22 and 14 for the ARINC word "E/53/350/00" are "0".
 NOTE:____ (E/53/350/00, BIT 22) = SRM-R VALID TRIM COMMAND SIGNAL -> SRM-L INTERFACE FAIL
 (E/53/350/00, BIT 14) = SRM-R SPEED TRIM ENGAGE SIGNAL -> SRM-L INTERFACE FAIL
 (9)  S 745-107Use the NEXT PAGE key on the CDU to show page 5 of the INPUT MONITORING.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 22-22-00
 ALL  ú ú 01 Page 512 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 745-108
 (10)
 Use the alphanumeric keys on the CDU to put "E/26/350/00" into the scratchpad.

 S 745-109

 (11)
 Push the LSK 1L to move the data into the correct position.

 S 745-110

 (12)
 Make sure that bits 22 and 14 for the ARINC word "E/26/350/00" are "0".


 NOTE: (E/26/350/00, BIT 22) = SRM-L VALID TRIM COMMAND SIGNAL ->
____
 SRM-R INTERFACE FAIL

 (E/26/350/00, BIT 14) = SRM-L SPEED TRIM ENGAGE SIGNAL -> SRM-R INTERFACE FAIL
 S 865-111
 (13) Open these circuit breakers:
 (a)  P7, Overhead Circuit Breaker Panel
 1) 7C16, FLT CONT ELEC 2R AC
 2) 7C17, FLT CONT ELEC 2R DC

 S 865-112
 (14)
 Stop for 5 to 10 seconds.

 S 865-113

 (15)
 Close these circuit breakers:

 (a)  P7, Overhead Circuit Breaker Panel
 1) 7C16, FLT CONT ELEC 2R AC
 2) 7C17, FLT CONT ELEC 2R DC


 (16)
 Make sure that bit 14 for the ARINC word "E/26/350/00" is "0".


 S 745-114
 NOTE: (E/26/350/00, BIT 14) = SRM-L SPEED TRIM ENGAGE SIGNAL ->
____
 SRM-R INTERFACE FAIL

 S 745-115
 (17) Use the PREV PAGE key on the CDU to show page 1 of the INPUT MONITORING.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 22-22-00
 ALL  ú ú 01 Page 513 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 745-116
 (18) Make sure that bit 14 for the ARINC word "E/53/350/00" is "0".
 NOTE: (E/53/350/00, BIT 14) = SRM-R SPEED TRIM ENGAGE SIGNAL ->
____
 SRM-L INTERFACE FAIL

 S 865-117
 (19) Open these circuit breakers:
 (a)  P7, Overhead Circuit Breaker Panel
 1) 7C10, FLT CONT ELEC 2L AC
 2) 7C11, FLT CONT ELEC 2L DC
 3) 7C12, FLT CONT ELEC 1L AC
 4) 7C13, FLT CONT ELEC 1L DC

 S 865-118
 (20)
 Stop for 5 to 10 seconds.

 S 865-119

 (21)
 Close these circuit breakers:


 (a)  P7, Overhead Circuit Breaker Panel
 1) 7C10, FLT CONT ELEC 2L AC
 2) 7C11, FLT CONT ELEC 2L DC
 3) 7C12, FLT CONT ELEC 1L AC
 4) 7C13, FLT CONT ELEC 1L DC

 S 745-120
 (22) Make sure that bit 14 for the ARINC word "E/53/350/00" is "0".
 NOTE: (E/53/350/00, BIT 14) = SRM-R SPEED TRIM ENGAGE SIGNAL ->
____
 SRM-L INTERFACE FAIL

 S 745-121
 (23)
 Use the NEXT PAGE key on the CDU to show page 5 of the INPUT MONITORING.

 (24)
 Make sure that bit 14 for the ARINC word "E/26/350/00" is "0".


 S 745-122
 NOTE: (E/26/350/00, BIT 14) = SRM-L SPEED TRIM ENGAGE SIGNAL ->
____
 SRM-R INTERFACE FAIL

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 空调 AUTO FLIGHT(192)