 (a)  
Elkee Formula-1
 Cyclo Manufactoring Co.
 Denver, CO


 (b)  
Head-O-Matic
 Alex Milne Ass.
 Ontario, CANADA


 (c)  
NFC A/C Toilet Deodorant
 George Industries
 Los Angeles, CA


 (d)  
Timsen Air Toilet Deodorant
 Unit Chemical Corp.
 Los Angeles, CA


 (e)  
Aerofresh
 Century Chemical Products
 Elkhart, IN


 (f)  
Sani-Pak 41-100
 Celeste Industries
 Easton, MD


 (g)  
Sanitex QC
 Selig Chemical Industries
 Atlanta, GA


 (h)  
HoneyBee 22
 McGean-Rohco, Inc.
 Downy, CA

 

 

 D. References
 (1)  
AMM 12-33-01/301, Cold Weather Maintenance

 (2)  
AMM 20-30-51/201, Miscellaneous Materials


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-17-00
 ALL  ú ú 03 Page 304 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 E. Access
 (1)  
Location Zones
 103 Forward Lavatory
 113 Left Aft Lavatory
 114 Right Aft Lavatory


 (2)  
Access Panels
 1104 Forward Toilet Panel
 1502 Toilet Service Door

 

 F. Procedure
 S 013-004
 (1)  Open the service panel and the toilet drain cap.
 NOTE: Fluid in the drain line can show leakage from the
____
 drain valve.

 S 863-007
 (2)  On the service panels without the levers for the flapper valve in the drain outlet, do these steps to connect the toilet service cart and to remove the drain plug.
 (a)  
Connect the Y-fitting to the drain outlet on the service panel.

 (b)  
Connect the flush line to the applicable flush port on the service panel.

 (c)  
Remove the drain plug with the T-handle on the Y-fitting. 1) Push the T-handle to engage the end of the rod with the mating part in the drain line plug. 2) Turn the T-handle counterclockwise until the drain line


 plug releases. 3) Pull the T-handle out until it stops.
 S 863-076
 (3)  On service panels with levers that open the flapper valve in the drain outlet, do these steps.
 (a)  
Connect the waste drain hose from the service cart to the toilet drain outlet on the service panel.

 (b)  
Connect the flush line to the applicable flush port on the service panel.

 (c)  
On service panels with the PUSH-TO-OPEN lever, push the PUSH-TO-OPEN lever to open the flapper valve.


 S 683-070
 CAUTION: MAKE SURE THAT NO PERSON FLUSHES A TOILET THAT HAS A DRAINED
_______ WASTE TANK. A PERSON WHO FLUSHES A TOILET THAT HAS A DRAINED WASTE TANK CAN CAUSE DAMAGE TO THE TOILET FLUSH MOTOR.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-17-00
 ALL  ú ú 04 Page 305 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 (4)  Do these steps to drain the toilet tank.
 (a)  Turn the handle for the waste drain valve until it is not locked.
 NOTE: The drain valve handle is not locked when you turn
____ it 90 degrees counterclockwise from the locked position.
 (b)  
Pull the handle for the waste drain valve.

 (c)  
To lock the drain valve handle in the extended (open) position, turn it 90 degrees clockwise.

 (d)  
Let the waste drain into the toilet service cart.


 NOTE: For the best flushing action of the drain lines,
____ drain the toilet tanks one at a time.
 S 863-013
 (5)  Turn the drain valve handle until it is not locked and release the drain valve handle to close the drain valve.
 S 173-087
 WARNING:_______DO NOT USE TOO MUCH TOILET FLUID DURING SERVICING. A LEAKAGE OF TOILET FLUID CAN POSSIBLY ENTER ELECTRICAL AND/OR ELECTRONIC SYSTEMS AND CAUSE A DANGEROUS MALFUNCTION. THIS COULD CAUSE AN UNWANTED EFFECT TO THE FLIGHT SAFETY OF THE AIRPLANE AND RESULT AS INJURY OR LOSS OF LIFE TO THE PERSONS ABOARD.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 SERVICING(85)