12-15-51
ALL ú ú 02.1 Page 309 ú Jul 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 TIRE INFLATION PRESSURE (PSI)
Air Refill Pressure
Figure 302
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
12-15-51
ALL ú ú 03 Page 310 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
T94728
A
737-300/400/500MAINTENANCE MANUAL
RAIN REPELLENT CONTAINER - SERVICING
____________________________________
1. General_______
A. This procedure contains a task to fill the rain repellent system.
B. The container for the rain repellent system is on the bulkhead adjacent to the observer's seat. Replace the container when the indicator on the reservoir shows it is necessary.
TASK 12-16-01-603-001
2. Rain Repellent Container Servicing (Fig. 301)__________________________________
A. Access
(1) Location Zone
101 Control Cabin - Left
B. Procedure
S 863-002
(1) Turn the shutoff valve handle to the closed (horizontal) position.
S 023-009
WARNING:_______DO NOT LET RAIN REPELLENT FLUID TOUCH YOUR SKIN OR EYES. THE FLUID CAN CAUSE IRRITATION. DO NOT BREATHE THE FUMES. IF THE FLUID TOUCHES YOU, WASH YOUR SKIN OR EYES WITH WATER.
(2) Remove the used container:
(a)
Release the clamp from the container.
(b)
Remove the container from the fitting.
S 213-004
(3) Make sure the new container will make a good seal:
(a)
See that the O-ring is satisfactory.
(b)
See that the top surface of the new container is satisfactory.
S 423-008
CAUTION:_______ONLY USE YOUR FINGERS TO TIGHTEN THE CONTAINER. TOO MUCH TORQUE CAN CAUSE LEAKS.
(4)
Install the new container:
(a)
Install the new container into the fitting.
(b)
Tighten the clamp around the container.
(5)
Turn the manual shutoff valve to the open (vertical) position.
S 863-006
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
12-16-01
ALL ú ú 02 Page 301 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
Rain Repellent Container Servicing
Figure 301
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
12-16-01
ALL ú ú 01 Page 302 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 213-007
(6) Make sure the fluid level indicator is at the full (top) position.
NOTE: If a new Rain Repellent container is installed and the fluid
____ level remains at the low level. Then removal and reinstallation of the Rain Repellent container is required to relieve the gas pressure. This allows the fluid level to show a new level.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 SERVICING(80)