 NOTE: The plunger of the master latch lock switch supplies
____ power to the circuit.
 (e)  
Manually or electrically operate the latches towards the unlatched position.

 (f)  
See that the green LATCHES CLOSED light on the door control panel goes off as the door unlatches.

 (g)  
Make sure that the DOOR SIDE CARGO (CAUTION) message shows on EICAS.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 52-71-00
 ALL  ú ú 06 Page 507 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (h)  Do this test of the EICAS messages: 1) Erase the applicable door status messages from EICAS if it
 is necessary. 2) Close, latch and lock the cargo door. 3) Make sure that the status message DOOR SIDE CARGO does not
 show on EICAS after 60 seconds.
 NOTE: The Door Up switch in the "door not up" position
____ does not allow the EICAS mesage to show.
 4) Open the side cargo door. 5) Push the plunger on the door latched switch and hold for a minimum of 60 seconds. 6) See that the DOOR SIDE CARGO (STATUS) message shows on EICAS.
 NOTE: The status message shows after you hold the
____
 plunger for more than one minute.

 7) Release the plunger on the door latched switch. 8) Erase the status message DOOR SIDE CARGO from EICAS. 9) Push the plunger on the door closed switch and hold for a
 minimum of 60 seconds. 10) See that the message DOOR SIDE CARGO (STATUS) shows on EICAS.
 NOTE: The status message shows after you hold the
____
 plunger for more than one minute.

 11) Release the plunger on the door closed switch.
 12) Erase the status message DOOR SIDE CARGO from EICAS.
 13) Push the plunger on the door warning switch and hold for a

 minimum of 60 seconds. 14) See that the message DOOR SIDE CARGO (STATUS) shows on EICAS.
 NOTE: The status message shows after you hold the
____
 plunger for more than one minute.

 15) Release the plunger of the door warning switch. 16) Erase the status message DOOR SIDE CARGO from EICAS. 17) Move the door until it is open between 1 and 2 feet. 18) Push and hold the plungers on the door warning switch and
 the door latched switch at the same time.
 NOTE: These steps do a test of the Door Closed circuit.
____
 19) See that the DOOR SIDE CARGO caution message shows on EICAS. 20) Push the plunger on the door closed switch while you continue to hold the plungers of the other switches.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 52-71-00
 ALL  ú ú 05 Page 508 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 21) See that the applicable caution message does not show on
 EICAS.
 22) Release the plungers of the three switches.
 23) Push the plunger of the door warning switch and the door
 closed switch.
 NOTE: These steps do a test of the Door Latched circuit.
____
 24) Make sure the DOOR SIDE CARGO caution message shows on EICAS. 25) Push the plunger on the door latched switch while you continue to hold the plungers of the other switches. 26) See that the DOOR SIDE CARGO caution message does not show on EICAS. 27) Release the plungers on the three switches.
 (i)  
Close and lock the side cargo door.

 (j)  
Make sure that the DOOR SIDE CARGO caution message does not show on EICAS.


 TASK 52-71-00-715-017
 6.  Operational Test of the Warning System for the Nose Cargo Door______________________________________________________________
 A.  References
 (1)  
AMM 24-22-00/201, Manual Control

 B.  
Access

 (1)  
Location Zone
 801 Nose Cargo Door


 C.  
Procedure


 S 715-083
 (1)  
Do the following operational test of the warning system for the Nose Cargo Door (Fig. 504).

 (a)  
Erase the EICAS status message DOOR NOSE CARGO if shown.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 舱门 DOORS 4(69)