• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-15 08:31来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

WEAR LIMITS MAXDIAMETER REPLACE
REPAIR INDEX
ALLOWED DIAM WORN WORN REPAIRWEAR CLEAR-
NO.
PART NAME DIM.
MIN
MAX
PART PART INSTR.
DIM.
ANCE
LATCH PLATE
OD
1 1
2
1

1
SHIMMING ADJACENT TO LATCH PLATE GIVES PROPER PLATE THICKNESS.
2
REPLACE WORN LATCH PAD WHEN WEAR ON PAD EXCEEDS 0.030 INCH.
Underwing Fuel Drain Door Wear Limits
Figure 601

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 52-49-08
 ALL  ú ú 01 Page 602 ú Jun 10/88
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 REFUELING ACCESS DOORS - MAINTENANCE PRACTICES
______________________________________________
 1.  General_______
 A.  This procedure contains these tasks:
 (1)  
A removal of the refueling access door

 (2)  
An installation of the refueling access door

 (3)  
An inspection/check of the refueling access door.

 B.  
The refueling access doors are located on the lower side of the wing near the leading edge. The refueling access doors consist of the fueling receptacle access doors on the left and right side and the fueling control panel access door on the left side.

 C.  
The forward edge of the door is attached with a hinge to the leading edge structure (Fig. 201).

 D.  
The aft edge of the door is held in position against the panel stiffeners with clamps.


 TASK 52-49-09-002-001
 2.  Refueling Access Door Removal____________________________
 A.  References
 (1)  
IPC 52-49-09 Fig. 1

 B.  
Access

 (1)  
Location Zone 543 Outbd. Main Tank (Part) Front Spar to Mid Spar, LH 643 Outbd. Main Tank (Part) Front Spar to Mid Spar, RH

 C.  
Remove the refueling access door (Fig. 201)


 S 022-002
 (1)  
Remove the door.

 (a)  
Disengage the quick-release clamps (2 per door) at the aft edge of the door and allow the door to move to the open position.

 (b)  
Remove the fasteners that attach the hinge to the leading edge structure.

 (c)  
Remove the fasteners that attach the bonding jumper cables to the stiffeners.

 (d)  
Remove the door.


 TASK 52-49-09-402-003
 3.  Refueling Access Door Installation__________________________________
 A.  References
 (1)  
28-21-04/401, Fueling Power Control Switch

 (2)  
51-24-04/701, Abrasion-Resistant Teflon Coating

 (3)  
IPC 52-49-09 Fig. 1

 B.  
Access

 (1)  
Location Zone 543 Outbd. Main Tank (Part) Front Spar to Mid Spar, LH 643 Outbd. Main Tank (Part) Front Spar to Mid Spar, RH


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 52-49-09
 ALL  ú ú 01 Page 201 ú Oct 10/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
FUELING CONTROL PANEL ACCESS DOOR
SEE B
FUELING RECEPTACLE ACCESS DOOR
SEE A
FUELING RECEPTACLE ACCESS DOOR
SEE A STIFFENERHOLD-OPEN ARMHOLD-OPEN ARM
HOLD-OPEN
HOLD-OPEN
PIN
PIN
FUELING RECEPTACLE  FUELING CONTROL PANEL 
ACCESS DOOR  ACCESS DOOR 
(EXAMPLE)  (EXAMPLE) 
A  B 
0.03 INCH 
(0.762 mm) 
MAXIMUM 
CLEARANCE 
(WEAR LIMIT)  STRIKER  LATCH BOLT 
1  PLATE 
SEE  C 
WEAR 
SURFACE 
0.338 INCH 
(12.95 |0.76 mm) 0.51 |0.03 INCH  LATCH  MINIMUM (8.58 mm) 
LATCH OVERLAP DIMENSION  A-A  (WEAR LIMIT) 

1  SHIM STRIKER PLATE IF WEAR LIMIT IS EXCEEDED  C 
2  REPLACE LATCH IF WEAR LIMIT IS EXCEEDED 

Refueling Access Door Installation
Figure 201

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 舱门 DOORS 4(61)