• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-15 08:31来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Make sure the message DOOR F/D OVHD does not show on EICAS.


 S 865-026
 (7) Remove electrical power if it is not necesary (AMM 24-22-00/201).
 TASK 52-71-00-715-005
 3.  Operational Test of the Warning System for the Forward and Aft Cargo Doors__________________________________________________________________________
 A. References
 (1)  
AMM 24-22-00/201, Manual Control

 (2)  
AMM 32-09-02/201, Air Ground Relays - Maintenance Practices

 B.
Access

 (1)  
Location Zone 122 Forward Cargo Container Compartment, Forward Half 142 Aft Cargo Container Compartment

 (2)  
Access Panel
 821R Door - Forward Cargo Compartment
 822R Door - Aft Cargo Compartment


 C.
Procedure


 S 865-009
 (1)  
Make sure the cargo doors are closed, latched and locked.

 S 715-010

 (2)  
Do a test of the door warning system on the forward (aft) cargo door.

 (a)  
Do this test of the door warning indication at the door control panel: 1) See that the green LATCHES CLOSED light on the door control


 panel is off.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 52-71-00
 ALL  ú ú 04 Page 503 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 (b)

(c)

(d)

(e)


A
747-400 MAINTENANCE MANUAL
 2) Open the master latch lock handle. 3) See that the green LATCHES CLOSED light on the door control panel is on.
 NOTE: The plunger of the master latch lock switch supplies
____
 power to the circuit.

Manually or electrically operate the latches towards the
 unlatched position.
See that the green LATCHES CLOSED light on the door control
 panel goes off as the door unlatches.
See that the applicable caution message shows on EICAS:
 1) DOOR FWD CARGO
 2) DOOR AFT CARGO.
Do a test of the EICAS messages.
 1) Erase the applicable door status message from EICAS, if it

 is necessary. 2) Close, latch and lock the cargo door. 3) Make sure the applicable door status message does not show
 on EICAS after 60 seconds.
 NOTE: The Door Up switch in the "door not up" position
____
 does not allow the status message to show.

 4) Open the door to the fully open position. 5) Push the plunger on the door latched switch and hold for a minimum of 60 seconds. 6) See that the applicable status message shows on EICAS:
 NOTE: The status message shows after you hold the plunger
____
 for more than one minute.

 a) DOOR FWD CARGO
 b) DOOR AFT CARGO. 7) Release the plunger on the door latched switch. 8) Erase the status message from EICAS.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 52-71-00
 ALL  ú ú 05 Page 504 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 9)  Push the plunger on the door closed switch and hold for a minimum of 60 seconds.
 10) See that the applicable status message shows on EICAS:
 NOTE: The status message shows after you hold the plunger
____
 for more than one minute.

 a)  DOOR FWD CARGO
 b)  DOOR AFT CARGO.
 11) Release the plunger on the door closed switch.
 12) Erase the status message on EICAS.
 13) Push the plunger on the door warning switch and hold for a minimum of 60 seconds.
 14) See that the applicable status message shows on EICAS:
 NOTE: The status message shows after you hold the plunger
____
 for more than one minute.

 a)  DOOR FWD CARGO
 b)  DOOR AFT CARGO.
 15) Release the plunger on the door warning switch.
 16) Erase the status message from EICAS.
 17) Move the door until it is open between 1 and 2 feet.
 18) Push and hold the plungers of the Door Warning Switch, the Door Latched Switch and the Door Closed Switches.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 舱门 DOORS 4(67)