S 866-015
(5)
Remove the DO-NOT-CLOSE tag and close this circuit breaker:
(a)
Main Power Distribution Panel, P6
1) 6J18 ENG START AIR CONT
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-11-00
ALL ú ú 12 Page 606 ú Oct 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(6) S 866-138Put the right isolation valve switch to close and the left isolation valve switch to open.
(7) S 866-139Put the APU VALVE switch to the ON position.
(8) S 866-140Pull out the applicable engine start switch on the P5 overhead panel.
S 866-141
WARNING: USE A RATCHET WRENCH TO TURN THE PRV MANUAL OVERRIDE DRIVE.
_______ THE PRV CAN OPEN QUICKLY WHEN YOU TURN THE MANUAL OVERRIDE DRIVE. THIS CAN PULL THE WRENCH OUT OF YOUR HANDS AND CAN CAUSE INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT
(9)
Carefully turn the PRV manual override drive on the applicable engine to the OPEN position.
(a)
Make sure that the PRV stays in the open position.
S 866-142
(10)
Put the APU VALVE switch to the OFF position when the MANIFOLD DUCT PRESSURE is stable.
S 216-022
(11)
Monitor the MANIFOLD DUCT PRESSURE on the auxiliary EICAS display and let the duct pressure fall to 30 psi by natural decay.
(a)
When the duct pressure reaches 30 psi, begin the stop watch or the pilot's clock to check the time necessary for the duct pressure to drop to 15 psi.
S 796-023
(12) If the time noted is 14 seconds or more, the system is acceptable. Otherwise, examine and repair the leakages from couplings, ducts, precooler, and equipment.
NOTE: A small quantity of leakage is permitted at the joints.
____ There must not be a high quantity of leakage at the joints. A high quantity of leakage can be felt by the hand from 12 inches away.
S 866-143
(13)
Open this circuit breaker and attach a DO-NOT-CLOSE tag:
(a)
P6 Main Power Distribution Panel 1) 6J18 ENG START AIR CONT
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-11-00
ALL ú ú 02 Page 607 ú Jun 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
S 866-060
(14)
Push the applicable engine start switch in to the off position.
S 866-144
(15)
Connect the electrical connector, DV351 to the applicable engine start valve.
S 866-036
(16)
Release the pressure from the pneumatic system if it is no longer necessary for other operations (Ref 36-00-00/201).
G. Check of Engine 3 or Engine 4 for Duct Leakage.
NOTE: Check the duct leakage for each engine separately.
____ S 016-028
(1)
Open the fan cowl panel (Ref 71-11-04/201).
S 016-029
(2)
Open the core cowl panel (Ref 71-11-06/201).
S 016-015
WARNING: DO THE DEACTIVATION PROCEDURE FOR THE THRUST REVERSER TO
_______ PREVENT THE OPERATION OF THE THRUST REVERSER. ACCIDENTAL OPERATION OF THE THRUST REVERSER CAN CAUSE INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT.
(3) Open the thrust reverser (Ref 78-31-00/201).
S 036-031
CAUTION: FAILURE TO DISCONNECT ELECTRICAL CONNECTOR WILL RESULT IN
_______
MOTORING OF ENGINE WHEN "START" SWITCH IS PULLED OUT.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 气动系统 PNEUMATIC SYSTEM(48)