747-400
MAINTENANCE MANUAL
40. PLUG SUPPLY PORT
41. PACKING 5. O-RING
42. SPRING JAMNUT4.
43. FILTER 3. ELBOW
44. SLEEVE
45. PACKING
PRECOOLER
PRESSURE
14. FLANGE PLATE
GROUND STUD
SEE C
FROM
FLOW FAN AIR
TEMPERATURE
3 SENSOR SIGNAL2 1
PRESSURE PORT
TEMPERATURE PORT
6. ELBOW
13. BOLT 7. UNION
12. WASHER 8. O-RING
11. NUT
(8 LOCATIONS) TERMINAL
BLOCK
9. WASHER
10. NUT
B
15. SELF-LOCKING BONDING
NUT JUMPER
16. PRESSURE
WASHER
17. ELECTROPLATED
BRASS PLAIN
CLEAN ELECTRICAL NUT
THIS AREA
18. CORROSION
PROTECTION
VALVE WASHER
GROUND STRAP
19. LOCKWASHER
20. GROUND STUD
C
Fan Air Modulating Valve Installation
Figure 401 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-12-04
ALL ú ú 01P Page 403 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 014-028
(2)
Open the right fan cowl panel (AMM 71-11-04/201).
S 014-037
(3)
Open the right core cowl panel (AMM 71-11-06/201).
S 014-029
WARNING: OBEY THE INSTRUCTIONS IN THE PROCEDURE TO OPEN THE THRUST
_______ REVERSERS. IF YOU DO NOT OBEY THE INSTRUCTION WHEN YOU OPEN THE THRUST REVERSER, INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR.
(4)
Open the right thrust reverser (AMM 78-31-00/201).
S 864-003
(5)
For the applicable engine, open this circuit breaker and attach a DO-NOT-CLOSE tag:
(a)
P6 Main Power Distribution Panel
1) 6H32 AIR SUPPLY CONT ENG 1
2) 6H33 AIR SUPPLY CONT ENG 2
3) 6H34 AIR SUPPLY CONT ENG 3
4) 6H35 AIR SUPPLY CONT ENG 4
D. Remove the Fan Air Modulating Valve
S 034-004
(1)
Disconnect and put tags on the three wires from the terminal block.
S 034-005
(2)
Disconnect the bonding jumper from the ground stud (20).
S 034-006
(3)
Disconnect the three tubes from the valve (1).
S 034-030
(4)
Remove the coupling (2).
(5)
Remove the fan air modulating valve (1).
S 034-008
(6)
If you install a new fan air modulating valve, do the steps that follow to remove the fittings from the used valve:
(a)
Remove the elbow (6), union (7), and O-ring (8) from the TEMP port. 1) Discard the O-ring (8).
(b)
Remove an elbow (3), union (4), and O-ring (5) from the SUPPLY port and the cooling air port. 1) Discard the O-rings (5).
S 024-031
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-12-04
ALL ú ú 01P Page 404 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(c)
Remove the eight bolts (13), washers (12), and nuts (11) to remove the flange plate (14).
(d)
Remove the ground stud (20) from the valve ground strap.
TASK 36-12-04-404-009
3. Install the Fan Air Modulating Valve (Fig. 401)____________________________________
A. Consumable Materials
(1)
D01062, Never-Seez, Pure Nickel Special, NSBT-8N (High temperature anti-seize cmpound)
(2)
G00095 Detector - Leak, Leak-Tek (160X)
B.
References
(1)
AMM 20-11-15/401, Bonding Jumpers and Ground Leads
(2) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 气动系统 PNEUMATIC SYSTEM(150)