(a)
Make sure the PRV is fully closed by visually checking the position switch.
(b)
If the PRV is open then replace the PRV (AMM 36-11-19/401).
(c)
Make sure the PRV shows CLOSED on the ECS maintenance page.
(d)
If the PRV is closed but does not indicate CLOSED on the ECS maintenance page, troubleshoot the position switch and/or wiring.
S 715-042
(3)
Test the PRV and the PRV controller operation.
(a)
Disconnect the PRV supply pressure tube and install the male fitting to the PRV controller supply pressure tubing.
(b)
Disconnect the PRV controller downstream (braided flex) line and install the 45 degree fitting to the PRV controller regulated pressure tubing.
(c)
Remove the PRV locking pin from the PRV actuator and install the actuator fitting. As an alternative, remove the signal pressure sense line at the actuator and install a tee fitting between the actuator and sense line.
(d)
Connect one end of the supply pressure (red) hose to the supply port on the test box and the other end to the male fitting in the PRV controller supply pressure tubing.
(e)
Connect one end of the regulated pressure (yellow) hose to the regulated pressure port on the test box and the other end to the 45 degree fitting in the PRV controller regulated pressure tubing.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-00-22
ALL ú ú 01 Page 512 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
PRESSURE REGULATING VALVE (PRV)
SEE B
PRV CONTROLLER
PRESSURE REGULATED
VALVE (PRV) REGULATING PRESSURE TUBE PRV CONTROLLER
SEE B DOWNSTREAM
REGULATING VALVE DOWNSTREAM PRESSURE 45` FITTING BRAIDED SENSE LINE
SENSE LINE FLEX LINE
SEE A
PW ENGINE PNEUMATICS TEST BOX REGULATED SUPPLY REFERENCE
PRESSURE PRESSURE PRESSURE PRV CONTROLLER SUPPLY PRESSURE TUBE
MALE FITTING
PRV SUPPLY PRESSURE TUBE
PRESSURE REGULATING VALVE FWD DOWNSTREAM SENSE LINE
A
LOCKING PIN
ACTUATOR PRESSURE ACTUATOR TUBE
TEE
FITTING SIGNAL PRESSURE TUBE
FWD REFERENCE
PRESSURE REGULATING VALVE (PRV)
PRESSURE
B
OPTIONAL INSTALLATION
Pressure Regulating Valve and Controller Figure 503 (Sheet 1)
H89053
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-00-22
ALL ú ú 01 Page 513 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
PRESSURE REGULATING
PRESSURE
VALVE DOWNSTREAM
REGULATING
SENSE LINE
VALVE
SEE C DOWNSTREAM
PRESSURE 45` SENSE LINE
REGULATING FITTING
VALVE CONTROLLER
BRAIDED
SEE D FLEX LINE
PW ENGINE
PNEUMATICS
REGULATED SUPPLY REFERENCE TEST BOX PRESSURE PRESSURE PRESSURE
PRV CONTROLLER LINE
MALE
FITTING
FWD
PRESSURE REGULATING VALVE DOWNSTREAM SENSE LINE
STRAIGHT FITTING C
ACTUATOR PRESSURE PORT
FWD
OUTBD
PRESSURE REGULATING VALVE CONTROLLER
D
Pressure Regulating Valve and Controller Figure 503 (Sheet 2)
L05439
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-00-22
ALL ú ú 01 Page 514 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(f)
Connect one end of the reference pressure (blue) hose to the reference pressure port on the test box and the other end to the actuator fitting or tee fitting.
(g) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 气动系统 PNEUMATIC SYSTEM(14)