(a)
Otherwise, refer to WDM 21-51-11, WDM 21-51-12, and
WDM 21-51-13 to do the appropriate continuity checks.
S 864-022
(34)
Put each of the PACK switches on the P5 panel to the "A" position, one at a time.
S 744-023
(35)
On airplanes equipped with S210U130-41 or -101 or newer PTCs, get access to the CMCS input monitoring to enter these input codes and to make sure that the bits are as follow: ~.................................................................. |E/5/35710 | Make sure that: | | | bits 14-19 = 0; bits 20-22 = 1; and bits 23-25 = 0; | .................................................................... |E/41/35710 | Make sure that: | | | bits 14-19 = 0; bits 20-22 = 1; and bits 23-25 = 0. | 2...........…......................................................1
(a)
Otherwise, refer to WDM 21-51-11, WDM 21-51-12, and
WDM 21-51-13 to do the appropriate continuity checks.
S 864-024
(36) Put each of the PACK switches on the P5 panel to the "B" position, one at a time.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-11-29
ALL ú ú 02 Page 409 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 744-025
(37)
On airplanes equipped with S210U130-41 or -101 or newer PTCs, get access to the CMCS input monitoring to enter these input codes and to make sure that the bits are as follow: ~................................................................ |E/5/35710 | Make sure that bits 14-22 = 0, and bits 23-25 = 1;| .................................................................. |E/41/35710 | Make sure that bits 14-22 = 0, and bits 23-25 = 1.| 2...........…....................................................1
(a)
Otherwise, refer to WDM 21-51-11, WDM 21-51-12, and WDM 21-51-13 to do the appropriate continuity checks.
S 214-026
(38)
Make sure that no bleed air is supplied to the air conditioning packs.
S 864-053
(39)
Open the applicable circuit breaker that follows and attach a DO-NOT-CLOSE tag:
(a)
On the overhead circuit breaker panel, P7
1) 7F35, PACK TEMP CONT A
2) 7F36, PACK TEMP CONT B
S 034-048
(40)
Disconnect the electrical connectors for the Pack 1, 2, and 3 flow control valves, DV93, DV95, and DV96, respectively.
S 214-044
(41)
Make sure that the voltage across pins 3 and 4 on each flow control valve connector (DV93, DV94, and DV95) is between 0 and 6 VDC.
S 864-046
(42)
Put each of the PACK switches on the P5 panel to the "OFF" position, one at a time.
S 214-045
(43)
Make sure that the voltage across pins 3 and 4 on each flow control valve connector (DV93, DV94, and DV95) is between 25 and 31 VDC.
E. Put the Airplane Back to Its Usual Condition
S 434-047
(1) Connect the electrical connectors for Pack 1, 2, and 3 flow control valves, DV93, DV95, and DV96, respectively.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-11-29
ALL ú ú 02 Page 410 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
(2) S 864-055Remove the DO-NOT-CLOSE tags and close the applicable circuit breakers that follows: (a) On the overhead circuit breaker panel, P7 1) 7F35, PACK TEMP CONT A 2) 7F36, PACK TEMP CONT B
(3) S 864-008Remove electrical power if it is not necessary (AMM 24-22-00/201).