(2)
AMM 20-41-02/201, Electrostatic Discharge Sensitive Devices
(3)
AIPC 28-41-02, Fig. 10
(4)
SSM 28-21-03, 28-21-04
(5)
WDM 28-21-21, 28-21-22, 28-21-23, 28-21-24
B.
Access
(1)
Location Zone 125 Area Below Forward Cargo Container Compartment, Left
(2)
Access Panel
125B Electronics Access Door
C.
Procedure
S 864-002
(1)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
(a)
On the main power distribution panel, P6: 1) 6D5, FUEL QTY 1 2) 6D6, FUEL QTY 2
(b)
On the DC power distribution panel, P180: 1) 180M8, FUELING VALVE 2 2) 180M9, FUELING PWR - HOT BAT
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-31
ALL ú ú 05 Page 401 ú Jun 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
FUEL QUANTITY
PROCESSOR UNIT
SEE A
ACCESS DOOR 125B
E6 RACK WINDOW
FWD
CARD (REF) ADJUSTMENT VTO REFUEL VALVE RELAY CARD QUANTITY CHANNEL INDIVIDUAL FUEL CARDS (REF) INPUT/OUTPUT CARDS (REF) FWD DOOR HINGED
Y5CA13
FUEL QUANTITY PROCESSOR UNIT (HINGED DOOR CLOSED)
A
HINGED EQUIPMENT
DOOR CARD NUMBER
REFUEL VALVE Y5CA013
RELAY CARD
FUEL QUANTITY PROCESSOR UNIT (HINGED DOOR OPEN)
A
Refuel Valve Relay Card
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-31
ALL ú ú 01 Page 402 ú Jun 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
(c) 3) 180C25, FUELING LTS PANEL 4) 180C26, FUELING LTS RECPOn the left power distribution center, P414: 1) 414F17, FUELING VALVE 2) 414F22, FUELING PWR
(2) S 014-003Open the electronics access door, 125B, to get access to the FQPU.
NOTE:____ The processor unit is immediately forward of the access door.
(3) S 014-004Open the front cover on the processor unit.
S 024-005
CAUTION: DO NOT TOUCH THE FUEL QUANTITY PROCESSOR UNIT BEFORE YOU DO THE
_______ PROCEDURE FOR DEVICES THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO THE FUEL QUANTITY PROCESSOR UNIT.
(4)
Do the procedure for devices that are sensitive to electrostatic discharge (AMM 20-41-02/201).
S 024-011
(5)
Remove the applicable I/O card from the FQPU (AMM 20-11-22/401).
TASK 28-21-31-404-006
3. Refuel Valve Relay Card Installation
____________________________________
A. References
(1)
AMM 20-11-22/401, Rack-Mounted Electrical/Electronic Module
(2)
AMM 20-41-02/201, Electrostatic Sensitive Devices
(3)
SSM 28-21-03, 28-21-04
(4)
WDM 28-21-21, 28-21-22, 28-21-23, 28-21-24
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn