28-21-12
ALL ú ú 04 Page 503 ú Jun 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
2) 180M9, FUELING PWR - HOT BAT
3) 180C25, FUELING LTS PANEL
4) 180C26, FUELING LTS RECP
(d)
On the left main power distribution panel, P414: 1) 414F17, FUELING VALVE 2) 414F22, FUELING PWR
(e)
On the right main power distribution panel, P415: 1) 415M14, FUEL OVERFILL CONTROL
G.
Do a Test of the Float Switches
S 865-011
(1) Make sure that the fuel quantity indicators on the P42 refuel control panel flash.
NOTE: This shows that the VTO override switch is in the ON
____
(override position).
S 865-012
(2)
Make sure that all of the refuel valve switches on the P42 panel are in the CLOSED position.
S 685-013
(3)
Use the fuel sampling receptacle assembly to drain the left wing surge tank (AMM 12-11-03/301).
S 685-014
(4)
Put a person at the drain valve for the left wing surge tank.
NOTE: Keep the drain valve open with the fuel sampling receptacle
____
assembly.
S 865-015
(5)
Set the RESERVE 2 refuel valve switch, found on the P42 panel, to the OPEN position.
S 655-016
(6)
Refuel the tank manually when there is approximately 10 psi maximum nozzle pressure (AMM 12-11-01/301).
NOTE: The 6 psi minimum fuel pressure is necessary to open the
____
refuel valve.
S 865-017
(7)
Make sure that the RESERVE 2 refuel valve indicator light comes on.
S 655-018
(8)
When you see fuel at the sump drain valve, stop the fuel flow immediately.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-12
ALL ú ú 13 Page 504 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
S 095-048
(9) Remove the fuel sampling receptacle assembly from the sump drain valve.
S 655-020
WARNING:_______THE SURGE TANK CAPACITY IS 125 GALLONS (473 LITERS). IF THERE IS MORE THAN THIS VOLUME FUEL WILL FLOW FROM THE WINGTIP VENT.
(10) Look at the flowmeter and add approximately 27 gallons (102 liters) of fuel to operate the overfill float switch.
NOTE: The REFUEL VALVE IN THE No. 2 reserve fuel tank will close.
____
This will stop the fuel flow.
S 865-021
(11)
Make sure that the OVERFILL indicator light, found on the P42 panel, is on and red.
S 865-022
(12)
Make sure that the RESERVE 2 refuel valve indicator light goes off.
S 655-023
(13)
Let the fuel drain from the surge tank for approximately eight minutes.
S 215-045
(14)
Make sure the drain valve with the fuel sampling receptacle assembly does not contain fuel.
S 655-049
(15)
Pressurize the fueling manifold.
S 865-050
(16)
Put the RESERVE 2 refuel valve switch in the OPEN position.
S 865-051
(17)
Make sure that the RESERVE 2 refuel valve indicator light does not come on.
(18)
Remove pressure from the fueling manifold.
(19)
Push the OVERFILL RESET switch found on the P42 panel.
(20)
Make sure that the red OVERFILL indicator light goes off.
S 655-025
S 865-026
S 215-044
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-12
ALL ú ú 05 Page 505 ú Feb 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 865-027
(21) Move the No. 2 reserve tank fuel to the No. 2 main tank with the RESERVE 2 & 3 XFER switch.
NOTE: The switch is found on the P461 pilots' overhead maintenance