(2)
Install the ignition unit (3) with the bolts (1).
(3)
TORQUE the bolts (1) to 40 lbf.in (0.45 m.daN).
(4)
Connect the igniter cables (2) to the ignition unit (3).
(5)
TORQUE the igniter cables (2) to between 26 and 32 lbf.in (0.29 and
0.36 m.daN).
(6)
Remove the blanking caps from the electrical connectors.
(7)
Make sure that the electrical connectors are clean and in the correct condition.
(8)
Connect the electrical connector P10 (4) to the ignition unit (3). Subtask 49-41-38-865-059
B.
Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1KD, 2KD.
Subtask 49-41-38-710-050
C. Do the self-test of the ECB (Ref. TASK 49-00-00-710-005).
5. Close-up
________ Subtask 49-41-38-410-052
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-410-001).
(3)
Remove the access platform(s).
(4)
Remove the warning notice(s). Subtask 49-41-38-865-060
B.
Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1KD, 2KD, 1WF, 2WF, 3WF, 4WF, 1QF
PLUG - IGNITER - REMOVAL/INSTALLATION
_____________________________________
R **ON A/C 001-003, 051-099, 401-499,
TASK 49-41-41-000-001 Removal of the Igniter Plug (8031KM) (GTCP 36-300) WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS
_______
WHEN YOU DO THE MAINTENANCE TASK(S).
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
No specific access platform 3.5 m (11 ft. 6 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action
52-41-00-010-001 Open the APU Doors for Access
49-41-41-991-001 Fig. 401
3. Job Set-up
__________ Subtask 49-41-41-860-055
A. Aircraft Maintenance Configuration
(1)
Energize the ground service network
(Ref. TASK 24-42-00-861-001).
(2)
On the panel 25VU, make sure that the APU MASTER SW pushbutton switch is off.
(3)
Put a warning notice in the cockpit to tell persons not to start the APU.
(4)
Make sure that hydraulic systems are depressurized
(Ref. TASK 29-00-00-864-001).
Subtask 49-41-41-865-050
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
Subtask 49-41-41-010-050
C. Get Access
(1)
Put the access platform in position below the APU access doors 315AL and 316AR.
(2)
Open the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-010-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER4(74)