 Subtask 49-32-11-010-052
 C. Get Access
 (1)
 Put the access platform in position below the APU access doors 315AL and 316AR.

 (2)
 Open the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-010-001).

 (3)
 Set the LIGHT control switch 11LJ to the on position.

 


 4. Procedure
_________ (Ref. Fig. 301/TASK 49-32-11-991-002) Subtask 49-32-11-210-051
 A. Inspection of the Fuel-Filter Differential-Pressure Indicator.
 (1)
 Examine the fuel-filter differential-pressure indicator (7). The indicator pin must not protrude from its housing.

 (2)
 If the indicator pin protrudes from its housing, you must change the fuel-filter (Ref. TASK 49-32-11-610-001).


 5. Close-up
________ Subtask 49-32-11-410-052
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Set the LIGHT control switch 11LJ to the off position.

 (3)
 Close the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-410-001).


 (4)
 Remove the access platform(s). Subtask 49-32-11-865-055

 B.
 Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1KD, 2KD


 Subtask 49-32-11-860-060
 C. Aircraft Maintenance Configuration
 (1)
 Pressurize the reservoirs of the hydraulic systems.
 (Ref. TASK 29-14-00-614-002).


 (2)
 De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).


 (3)
 Remove the warning notice(s).

 


 Fuel Filter
 Figure 301/TASK 49-32-11-991-002

 CES  TASK 49-32-11-610-001


 Servicing of the Fuel Filter (GTCP 36-300)
 WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS
_______ WHEN YOU DO THE MAINTENANCE TASK(S).
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific blanking plugs
 No specific circuit breaker(s) safety clip(s)
 No specific lint free cloth
 No specific container 10 l (2.6416 USgal)
 No specific access platform 2.5 m (8 ft. 2 in.)
 No specific Torque Wrench : range 0.00 to 1.20 m.daN

 (0.00 to 9.00 lbf.ft)
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 01-002 USA MIL-PRF-5624 GRADE JP4 FUEL, TURBO (Ref. 20-31-00) Material No. 01-003 USA MIL-T-5624 GRADE JP5 FUEL, TURBO (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
4 o-ring 49-32-11 01 -040 5 fuel filter 49-32-11 01 -050 6 o-ring 49-32-11 01 -060


 D. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 28-22-00-710-001 Operational Test of the APU Fuel-Pump System on Ground to Purge the Fuel Line 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector 49-00-00-860-003 APU Start by External Power (GTCP 36-300) 49-00-00-860-004 APU Shutdown by External Power (GTCP 36-300) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access 49-32-11-991-002 Fig. 301
 3. Job Set-up
__________
 Subtask 49-32-11-860-061
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).


 (2)
 On the panel 25VU, make sure that the APU MASTER SW pushbutton switch is off.

 (3)
 Put a warning notice in the cockpit to tell persons not to start the APU.
 