(3)
Disconnect the dummy connector from the electrical connector (P33).
(4)
Make sure that the electrical connectors are clean and in the correct
condition.
(5)
Connect the electrical connector (P33) to BCV.
(6)
Do the operational test of the APU (Ref. TASK 49-00-00-710-008).
(7)
If the test gives the Maintenance Message BLD FLOW XDCR (8039KM), do the Trouble Shooting procedure (Ref. TSM 490000810903).
(8)
If the test gives the Maintenance Message BLEED CTL VLV (8051KM), do the Trouble Shooting procedure (Ref. TSM 490000810904).
(9)
If the test gives the Maintenance Message IGV ACTR (8014KM), do the Trouble Shooting procedure (Ref. TSM 490000810905).
5. Close-up
________ Subtask 49-51-00-410-054
A. Close Access
(1)
Set the LIGHT control switch 11LJ to the off position.
(2)
Make sure that the work area is clean and clear of tool(s) and other items.
(3)
Close the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-410-001).
(4)
Remove the access platform(s).
(5)
Remove the warning notice(s).
(6)
De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002)
SENSOR ASSY - PNEUMATIC - REMOVAL/INSTALLATION
______________________________________________ R **ON A/C 001-003, 051-099, 401-499,
TASK 49-51-13-000-001 Removal of the Pneumatic Sensor Assy (GTCP 36-300) WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS
_______
WHEN YOU DO THE MAINTENANCE TASK(S).
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information