 De-energize the ground service network
 (Ref. TASK 24-42-00-862-001).


 (3)
 Remove the warning notice(s).

 


 FILTER - FUEL - MAINTENANCE PRACTICES
_____________________________________
 TASK 49-32-41-920-002
 Replacement of the Fuel Filter (8028KM) (APS 3200)
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific blanking cap
 No specific circuit breaker(s) safety clip(s)
 No specific lint free cloth
 No specific warning notice
 No specific container 1.0 l (0.2641 USgal)
 No specific access platform 3.5 m (11 ft. 6 in.)

 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 01-002 USA MIL-PRF-5624 GRADE JP4 FUEL, TURBO (Ref. 20-31-00) Material No. 01-003 USA MIL-T-5624 GRADE JP5 FUEL, TURBO (Ref. 20-31-00)


 C. Expendable Parts -------------------------------------------------------------------------------
FIG.ITEM --------- |DESIGNATION ---------------------------------------- |IPC-CSN------------------------------
1  packing  49-32-11 50 -020
 2  packing  49-32-11 50 -040
 2  packing  49-32-11 50 -040A
 2  packing  49-32-11 50 -040B
 3  filter element  49-32-11 50 -030
 3  filter element  49-32-11 50 -030A
 D. Referenced Information
 ------------------REFERENCE  -------------------------------DESIGNATION ------------------------------

-------------------------------------------------------------------------------
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 24-42-00-861-001 Energize the Ground Service Network from the External
 Power 28-00-00-910-001 Fuel Safety Procedures 28-22-00-710-001 Operational Test of the APU Fuel-Pump System on
 Ground to Purge the Fuel Line 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 49-00-00-860-005 APU Start by External Power (APS 3200) 49-00-00-860-006 APU Shutdown by External Power (APS 3200) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access 49-32-41-991-004 Fig. 201
 3. Job Set-up
__________
 Subtask 49-32-41-941-055
 A. Safety Precautions
 (1) Obey the Fuel Safety Procedures (Ref. TASK 28-00-00-910-001).


 Subtask 49-32-41-860-054
 B. Aircraft Maintenance Configuration
 (1)
 Energize the ground service network
 (Ref. TASK 24-42-00-861-001).


 (2)
 On the panel 25VU, make sure that the APU MASTER SW p/bsw is OFF.

 (3)
 Put a warning notice in the cockpit to tell persons not to start the APU.

 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-00-00-864-001).

 

 Subtask 49-32-41-865-059
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU APU/FUEL/BLOW OFF/PUMP 2QC B14 49VU AIR BLEED/X FEED/VALVE/BAT 2HV D13 121VU APU/FUEL/BLOW OFF/CTL 1QC K39 121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41 121VU APU/FUEL/LP VALVE/CTL 1QF M40 121VU APU/FUEL/LP VALVE/SPLY 2QF M39 121VU APU/FUEL/PUMP/CTL 3QC M38
 Subtask 49-32-41-010-053
 D. Get Access
 (1)
 Put the access platform below the APU access doors 315AL and 316AR.

 (2)
 Open the access doors 315AL, 316AR (Ref. TASK 52-41-00-010-001).

 (3)
 Set the LIGHT control SW 11LJ to the ON position.

 


 4. Procedure
_________
 (Ref. Fig. 201/TASK 49-32-41-991-004) Subtask 49-32-41-020-053
 A. Filter Housing/Element - Removal
 (1)
 Put the container in position below the fuel filter housing (4).

 (2)
 Grasp the filter housing (4), turn it anti-clockwise and remove it.

 (3)
 Let the fuel from the fuel filter housing (4) drain into the container.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER4(61)