 49-52-08
 ALL  ú ú 01 Page 405 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 P3 AIR FILTER ELEMENT - CLEANING/PAINTING
_________________________________________
 1.  General_______
 A. This procedure has the task to clean the P3 air filter element.
 TASK 49-52-08-107-010
 2.  P3 Air Filter Element Cleaning______________________________
 A. Equipment
 (1)  
Ultrasonic Sump

 (2)  
Engraving Tool

 B.
Consumable Materials

 (1)  
B00442 Acid - Nitric, Tech Grade 42° Baume

 (2)  
B00440 Powder - Cupric Sulphate

 (3)  
B00441 Solution - Ammonium Hydroxide

 (4)  
G00604 Solution - Sodium Hydroxide

 (5)  
B00436 Solvent - Carbon Removing, Magnus 755

 (6)  
B00453 Solvent - Cleaning, Freon TF

 C.
References

 (1)  
AMM 49-52-08/401, P3 Air Filter Element

 D.
Access

 (1)  
Location Zones 310 Fuselage - Station 2360 to Station 2792

 (2)  
Access Panels
 317AL APU Access Door - Left
 318AR APU Access Door - Right


 E.
Procedure

 (1)  
Do this task: P3 Air Filter Element Removal (AMM 49-52-08/401).

 S 137-008

 (2)  
Use the ultrasonic cleaner to clean the element for the P3 air filter.

 (a)  
Put the element in the carbon removing solvent for 30-60 minutes.


 S 027-017
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 49-52-08
 ALL  ú ú 02 Page 701 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (b)  Increase the temperature of the cleaning fluid to 118°F (48°C).
 NOTE: The boiling point of the cleaning fluid is 117.6°F
____
 (47.6°C).

 (c)  
Put the element in the hot cleaning fluid.

 (d)  
Flush the element in the opposite direction at a flow rate of 1.2-3.6 U.S. gallons (4.5-13.6 liters) for each minute at 100°F (38°C) and 30 psig (207 kPa).

 (e)  
Ultrasonic clean the element for 1-3 minutes at a minimum frequency of 25 kHz.

 (f)  
Turn the element 180 degrees.

 (g)  
Continue to flush the element in the oposite direction and ultrasonic clean the element for 1-3 minutes.

 (h)  
Make sure the cooling water in the water jacket is less than 80°F (27°C).

 (i)  
Hold the element in the cleaning fluid gas (below the water jacket level) for 1-5 minutes at 118°F (48°C).


 NOTE: The condensation temperature of the gas is approximately
____
 100°F (38°C).

 (j)  
Continue to flush the element in the opposite direction and ultrasonic clean the element for 1-3 minutes.

 (k)  
Drain the element above the water jacket level for 1-5 minutes.

 (l)  
Make sure the cooling system is on for a minimum of 30 minutes after the ultrasonic sump is off.

 (m)  
Dry the element with the air for 1-3 minutes.


 S 217-011
 (3)  
Examine the element for lint particles.

 (a)  
Remove all of the lint particles with the air.


 NOTE: You can use a plastic or a wood pick to remove the
____
 lint.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 49-52-08
 ALL  ú ú 02 Page 702 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (b) If lint particles continue to show, do the steps that follow.
 1)  Prepare a solution to remove the lint. a) Mix cupric sulphate powder with the water at a ratio of
 13.3 ounces for each gallon (100 grams for each liter). b) Isolate a solid from the solution with sodium
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 机载辅助动力 2(99)