 49-31-00
 ALL  ú
 ú  01  Page 5
 ú  Feb 18/02 

BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

SHT 1  A  SECONDARY SHUTOFF SOLENOID  FUEL METERING UNIT 
HIGH PRESSURE RELIEF VALVE  METERING VALVE  MINIMUM PRESSURE VALVE 
SHT 1  B 
SHT 1  C  STEPPER MOTOR AND RESOLVER  CONTROLLER TO APU FROM APU CONTROLLER 
VALVE REGULATING PRESSURE  SERVO REGULATOR SUPPLY 
SOLENOID SHUTOFF PRIMARY  FUEL FILTER  CONTROL DIVERTER VALVE ACTUATOR AND PRESSURE TO IGV SERVO REGULATED 
Figure 2 (Sheet 2) APU Fuel System Schematic 

M32451
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 49-31-00
 ALL  ú ú 03 Page 6 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 A.  APU fuel flow is controlled by the APU controller in conjunction with the fuel metering unit (FMU). Pressurized fuel from the fuel pump flows through an adapter plate to the FMU. The APU controller provides control signals to the stepper motor and metering valve, in the FMU, to regulate fuel flow in response to load demands. Metered fuel is supplied to the combustion chamber through a fuel flow divider and dump valve together with independent distribution manifolds radially arranged around the gas generator case. The flow divider distributes the flow between primary and secondary fuel nozzles projected into the combustion chamber. Any residual fuel after shutdown is drained by drain valves located at the bottom of the gas generator case. Pressurized fuel is supplied to the inlet guide vane (IGV) actuator control and the diverter valve control to be used as hydraulic fluid. Fuel through the fuel cooled oil cooler (FCOC) maintains oil temperature in the lubrication system feed line within operating limits by heat exchange with high pressure fuel.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 49-31-00
 ALL  ú ú 01 Page 7 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 FAULT ISOLATION/MAINT MANUAL
APU ENGINE FUEL SYSTEM
COMPONENT  102 SHT FIG.  QTY  ACCESS/AREA  AMM REFERENCE 
ADAPTER - FUEL METERING  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-02 
ADAPTER - NOZZLE  14  317AL, 318AR/310 (APU COMPARTMENT)  49-31-04 
FILTER - FUEL PUMP OUTLET  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-00 
INDICATOR - FUEL FILTER BYPASS  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-05 
MANIFOLD - PRIMARY FUEL  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-04 
MANIFOLD - SECONDARY FUEL  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-04 
PLUG - FUEL PUMP COVER  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-00 
PUMP- FUEL  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-03 
SCREEN - FUEL PUMP INLET  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-00 
UNIT - FUEL METERING, M3374  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-01 
VALVE - FLOW DIVIDER AND DUMP  1  317AL, 318AR/310 (APU COMPARTMENT)  49-31-00 

APU Engine Fuel System - Component Index
Figure 101

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 49-31-00
 ALL  ú ú 01 Page 101 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

747-400
FAULT ISOLATION/MAINT MANUAL

FUEL COOLED 
317AL, 318AR  FWD  OIL COOLER 
APU COMPT  (REF) 
SEE  A 

FUEL PUMP, 
FUEL METERING UNIT, 
FUEL METERING ADAPTER 
FUEL MANIFOLDS, 
FUEL NOZZLES,  SEE  B 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 机载辅助动力 2(30)