28-31-14
ALL ú ú 03 Page 507 ú Oct 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
H. Test of the Main No. 2 Aft Pump, M223, Ground Fault Detector, M7867
S 865-038
(1)
Make sure that the main No. 2 OVRD AFT pump switch on the fuel management module, M154, is set to the OFF position.
S 865-039
(2)
Make sure that L CTR and CTR R switches on M154 are set to the OFF position.
S 865-040
(3)
Remove the connector, DM223, from the main No. 2 aft
override/jettison pump, M223.
S 865-041
(4)
Make sure that the LOAD switch on test equipment G28013 is in the OFF position.
S 865-042
(5)
Connect DM223 to test equipment G28013.
S 865-043
(6)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a)
P180 DC Power Distribution Panel 1) 180E18 FUEL OVRD/JTSN PUMP CONT AFT 2 & 3
(b)
P415 Power Distribution Center - Right
1) 415A38 FUEL OVRD/JTSN PUMP AFT 2
S 865-045
(7)
Set the No. 2 main OVRD AFT pump switch on module M154 to the ON position.
S 715-046
(8)
See that the test equipment POWER PHASE ON indicator lights for phase A, B, and C come on.
(9)
Set the LOAD switch on the test equipment to the LOAD position.
S 715-048
(10)
See that the test equipment POWER PHASE ON indicator lights for phases A, B, and C go off.
S 865-047
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-31-14
ALL ú ú 03 Page 508 ú Feb 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 865-049
(11)
Set the No. 2 main OVRD AFT pump switch on module M154 to the off position.
S 865-050
(12)
Set the LOAD switch on the test equipment to the OFF position.
S 865-051
(13)
Open these circuit breakers and attach a DO-NOT-CLOSE tags:
(a)
P180 DC Power Distribution Panel 1) 180E18 FUEL OVRD/JTSN PUMP CONT AFT 2 & 3
(b)
P415 Power Distribution Center - Right
1) 415A38 FUEL OVRD/JTSN PMP AFT 2
S 865-053
(14)
Remove the connector, DM223, from the test equipment.
S 865-054
(15)
Connect DM223 to pump M223.
I.
Test of the Center Tank Right Side Pump, M225, Ground Fault Detector, M472
S 865-055
(1)
Make sure the CTR R pump switch on the fuel management module, M154, is set to the OFF position.
S 865-056
(2)
Remove the connector, DM225, from the center tank right override/jettison pump, M225, in the wheel well of the right wing landing gear.
S 865-057
(3)
Make sure that the LOAD switch on test equipment G28013 is in the OFF position.
(4)
Connect DM225 to test equipment G28013.
S 865-059
(5)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a)
P180 DC Power Distribution Panel
1) 180H18 FUEL OVRD/JTSN PMP CONT CTR R
S 865-058
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-31-14
ALL ú ú 03 Page 509 ú Feb 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(b) P415 Power Distribution Center - Right
1) 415M32 FUEL OVRD/JTSN PUMP CTR RIGHT
S 865-061
(6)
Set the CTR R pump switch on the fuel management module, M154, to the ON position.
S 715-062
(7)
See that the test equipment POWER PHASE ON indicator lights for phases A, B, and C come on.
S 865-063
(8)
Set the LOAD switch on the test equipment to the LOAD position.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 燃油 FUEL 4(73)