• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-11 09:15来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


 S 014-010
 (1)  
If the circuit cards are not removed, do the steps that follow:

 (a)  
Open these circuit breakers and attach DO-NOT-CLOSE tags:


 1)  On the main power distribution panel, P6: a) 6D5, FUEL QTY 1
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-41-13
 ALL  ú ú 06 Page 405 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 b)  6D6, FUEL QTY 2
 2)  On the DC power distribution panel, P180: a) 180M8, FUELING VALVE 2 b) 180M9, FUELING PWR - HOT BAT c) 180C25, FUELING LTS PANEL d) 180C26, FUELING LTS RECP
 3)  On the left power distribution center, P414: a) 414F17, FUELING VALVE b) 414F22, FUELING PWR
 (b)  Open the electronics access door, 125B, to get access to the fuel quantity processor unit.
 NOTE: The fuel quantity processor unit is immediately forward
____ of the electronics access door.
 (c)  Open the door on the fuel quantity processor unit.
 S 034-012
 (2)  
Disconnect all the electrical connectors from the fuel quantity processor unit.

 S 034-013

 (3)  
Disconnect the cooling air hose from the side of the fuel quantity processor unit.

 S 024-014

 (4)
Remove the fuel quantity processor unit (AMM 20-11-22/401).


 TASK 28-41-13-404-054
 5.  Fuel Quantity Processor Unit (FQPU) Installation (Fig. 401)
________________________________________________
 A.  References
 (1)  
AMM 20-11-22/401, E/E Rack-Mounted Components

 (2)  
AMM 24-22-00/201, Manual Control

 (3)  
AIPC 28-21-52, Fig. 1

 (4)  
SSM 28-41-02, 28-41-03, 28-41-04, 28-41-05

 (5)  
WDM 28-41-12, 28-41-21, 28-41-22, 28-41-23, 28-41-24


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-41-13
 ALL  ú ú 06 Page 406 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 B.  Access
 (1)  
Location Zone 125 Area Below Forward Cargo Container Compartment, Left

 (2)  
Access Panel
 125B Electronics Access Door


 C.  
Procedure


 S 424-061
 (1)  
Install the fuel quantity processor unit on the E6 equipment rack (AMM 20-11-22/401).

 S 434-062

 (2)  
Connect the cooling air hose to the side of the fuel quantity processor unit.

 S 434-063

 (3)  
Connect all the electrical connectors to the fuel quantity processor unit.


 NOTE: Make sure the connectors are in the correct location.
____
 S 434-064
 (4)  
If the circuit cards are not installed in the new FQPU, do this task: "Fuel Quantity Processor Unit Circuit Cards Installation".

 S 414-065

 (5)  
If all the circuit cards are installed in the new FQPU, do the steps that follow:

 (a)  
Supply electrical power, if it is not available (AMM 24-22-00/201).

 (b)  
Remove the DO-NOT-CLOSE tags and close these circuit breakers:


 1)  On the main power distribution panel, P6: a) 6D5, FUEL QTY 1 b) 6D6, FUEL QTY 2
 2)  On the DC power distribution panel, P180: a) 180M8, FUELING VALVE 2 b) 180M9, FUELING PWR - HOT BAT
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-41-13
 ALL  ú ú 05 Page 407 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.

747-400 
MAINTENANCE MANUAL
 c)  180C25, FUELING LTS PANEL
 d)  180C26, FUELING LTS RECP
 3)  On the power distribution center, P414:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 燃油 FUEL 4(138)