d) medium to heavy corrosion damage (reference the 747 Corrosion Prevention Manual, CPM 20-40-00, Part I, General Information - Corrosion Removal Techniques, Paragraph 3.A).
S 214-191
(3)
If the visual check shows that the fuel pump is OK, do this
procedure: Fuel Pump Continuity Check.
S 214-192
(4)
If the visual check shows that the fuel pump is not OK, do these steps:
(a)
Replace the override/jettison pump motor/impeller unit.
(b)
Do the continuity/resistance checks for the replacement fuel pump. 1) Start with this procedure: Fuel Pump Continuity Check.
G.
Fuel Pump Continuity Check
S 014-193
(1) Disconnect the electrical connector from the pump motor/impeller unit.
S 864-194
WARNING: MAKE SURE THE METER USED TO MEASURE THE BONDING JUMPER
_______ CONTINUITY IS RESISTANT TO EXPLOSION. IF NOT, IT IS POSSIBLE THAT AN EXPLOSION OR FIRE CAN OCCUR.
(2)
Use the AVTRON Model T477W bonding meter (SWPM 20-20-00, para I).
S 764-195
(3)
Measure the resistance between pin 4 of the electrical connector and the braided bonding jumper on the fuel pump (Fig. 402, View B).
NOTE: The measurement between pin 4 and the bonding jumper is a
____ continuity check, not a bonding resistance check.
S 974-196
(4)
Record the resistance measured between pin 4 and the braided bonding jumper on the data sheet (Fig. 403).
S 764-197
(5)
If the resistance is less than or equal to 1.99 ohms, do this procedure: Initial Insulation Resistance Check.
S 764-198
(6)
If the resistance is more than 1.99 ohms, do these steps:
(a)
Replace the override/jettison pump motor/impeller unit.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-31-01
ALL ú ú 01 Page 424 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(b)
Do the continuity/resistance checks for the replacement fuel pump. 1) Start with this procedure: Fuel Pump Continuity Check.
H.
Initial Insulation Resistance Check
S 764-199
CAUTION:_______DO THE RESISTANCE CHECK AT 10 VDC FIRST. THE FUEL PUMPS ARE IN FLAMMABLE LEAKAGE ZONES. EACH PUMP IS TESTED AT 10 VDC BEFORE IT IS TESTED AT 500 VDC. THE INITIAL 10 VDC CHECK IS TO FIND OUT IF A FUEL PUMP HAS LOW INSULATION RESISTANCE WHICH CAN ARC OR OVERHEAT WHEN A HIGH VOLTAGE IS APPLIED. THE RESULTS OF THE 10 VDC CHECK WILL TELL YOU IF IT IS SAFE TO DO THE 500 VDC CHECK WITH THE FUEL PUMP INSTALLED ON THE AIRPLANE.
(1) Do these steps to check the insulation resistance (initial check):
NOTE: These steps are done at 10 VDC to prevent arcing or
____ overheat in a flammable leakage zone when high voltage is applied to a pump with low insulation resistance.
(a)
Do this procedure: Calibrate the QuadTech Model 1864 megohmmeter.
(b)
Disconnect the electrical connector from the pump motor/impeller unit.
WARNING: MAKE SURE A QUADTECH MODEL 1864 (OR EQUIVALENT)
_______ MEGOHMMETER IS USED TO MEASURE THE INSULATION RESISTANCE. IF NOT, IT IS POSSIBLE THAT AN EXPLOSION OR FIRE CAN OCCUR.