• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 23:22来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 33-15-00
 ALL  ú ú 01 Page 102 ú Jul 15/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
TROUBLE  PROBABLE CAUSE  ISOLATION PROCEDURE  REMEDY 
Left (or right) system master caution annunci-ator section is not recalled when annunciator is momentarily pressed Recall and master test functions for both master caution annunci-ators inoperative  System module logic or system master caution annunciator inoperative Short to ground in a master caution annunci-ator recall switch, or master test relay (R33), or system wiring  Observe which system indi-cator lights are illumi-nated on P5 modules. Momentarily press left (or right) system master Using system wiring dia-grams, isolate short to component or wiring caution annunciator. Ob-serve corresponding system master caution annunciator sections illuminate. If none illuminate, annunci-ator is faulty. If only one anunciator section does not illuminate, relamp section and retest. If section still does not il-system module is faulty luminate, corresponding  Replace system master caution annunciator. Relamp annunci-ator. Replace system module Replace compo-nent (master caution annunci-ator module or master test relay) or repair wiring as appli-cable 

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-15-00
 ALL  ú ú 01 Page 103 ú Oct 25/84
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
3. Master Dim and Test Trouble Shooting Chart
TROUBLE  PROBABLE CAUSE  ISOLATION PROCEDURE  REMEDY 
System indicator  Burned out bulb  Hold LIGHTS switch to TEST.  Relamp system 
light does not  Observe system indicator  indicator light 
illuminate or is  light illuminates. If not, 
dim when LIGHTS  bulb is faulty 
switch held to 
TEST 
Group of lights  Master test relay  Hold LIGHTS switch to TEST.  Replace master 
do not illuminate  contact open or  Observe group of lights do  test rely R33. 
when LIGHTS  one dim relay has  not illuminate  Replace master 
switch held to TEST  contacts open  Master test relay R33 or a dim relay is probably faulty  dim module M564. Replace master dim relay R34. Replace auxiliary 
through each relay to isolate faulty relay (Refer to Wiring Diagram Manual for specific circuits) Conduct continuity check  master dim relay R87 
All lights do not  LIGHTS switch  Hold LIGHTS switch to TEST.  Replace LIGHTS 
illuminate when  S270 inoperative  If lights do not illumi- switch S270 
LIGHTS switch  nate, switch is faulty 
held to TEST 
Group of lights  Open zener diode  Position LIGHTS switch to  Replace either 
go off when  DIM. Observe which lights  M207,M208,M209, 
LIGHTS switch  go off. Check continuity  M210 or M394 
positioned to DIM  of zener diodes M207,M208, M209,M210 and M394 in load control center P6 to iso-late faulty zener diode. (Refer to Wiring Diagram Manual to check lights on specific zener diode circuit) 

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-15-00
 ALL  ú ú 01 Page 104 ú Oct 25/84
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
TROUBLE  PROBABLE CAUSE  ISOLATION PROCEDURE  REMEDY 
(1) Pilot's Autopilot Disengage Light Copilot's Autopilot Disengage Light Master Caution Lights and Annunciators Antiskid Light (2) (3) (4) When LIGHTS switch is held to TEST position, if one of following sys-tem indicator lights does not illuminate:  Open transistor-diode dimming circuit in M469 annunciator and dimming  Relamp system indicator light. Hold LIGHTS switch to TEST. If light is still inoperative, annunciation and dimming module is faulty  Replace M469 annunciation and dimming module 

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 灯 LIGHTS(20)