• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-09 10:23来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 24-21-03
 ALL  ú ú 05 Page 402 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
E13648
A
747-400
MAINTENANCE MANUAL

4.  SCREW (4 LOCATIONS)
6.  AIR INLET DUCT
27. NUT
26. SPACER
1. ELECTRICAL CONNECTOR 
(DG3B)  AIR EXHAUST 
DUCT CLAMP 
3. AIR EXHAUST DUCT 
25. ELECTRICAL CONNECTOR 
(DG3A)  C 

4.  SCREW (4 LOCATIONS)
27. NUT
6.  AIR INLET DUCT
26. SPACER
AIR EXHAUST DUCT CLAMP
10. ELECTRICAL CONNECTION, DG2B
14. ELECTRICAL CONNECTOR, DG2A
3.  AIR EXHAUST DUCT
D
APU-Driven Generator Installation Figure 401 (Sheet 2)
E13660
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-21-03
 ALL  ú ú 06 Page 403 ú Jun 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

747-400
MAINTENANCE MANUAL

RIGHT APU GENERATOR SLING ATTACH POINT
SEE A
LEFT APU GENERATOR SLING ATTACH POINT
SEE A
SEE B
A 2669.52 STA 
A  APU GENERATOR SLING ATTACHMENT POINT 

APU HOIST
ATTACHMENT
POINT

FWD
APU GENERATOR SLING ATTACHMENT POINT
(LEFT SIDE IS SHOWN, RIGHT SIDE IS OPPOSITE)

A

Auxiliary Power Unit Generator Sling Installation Figure 402 (Sheet 1)
L83299
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-21-03
 ALL  ú ú 01 Page 404 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL


FWD

Auxiliary Power Unit Generator Sling Installation
Figure 402 (Sheet 2)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-21-03
 ALL  ú ú 02 Page 405 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
L83576
A
747-400
MAINTENANCE MANUAL

 S 944-104
 (2)  For the applicable generator, open this circuit breaker and attach a DO-NOT-CLOSE tag. (a) P180-1 Power Distribution Panel 1) 180L1 AGCU 1 2) 180M1 AGCU 2
 S 014-121
 (3)  Open the latches on the APU access doors.
 S 014-105
 (4)  Open the APU access doors (317AL, 318AR).
 S 944-106
 (5)  Engage the door support rods.
 S 024-093
 (6)  Disconnect the electrical connectors (1, 25 or 10, 14) from the generator (2 or 11).
 S 024-094
 (7)  Remove the phase leads (12 or 13) from the generator terminal studs. (a) Remove the terminal block cover (16) from the generator (2 or 11). (b) Put phase identification tags on the phase leads. (c) Remove the terminal nuts (17) and washers (19) that attach the phase leads to the generator terminal studs. (d) Remove the phase lead terminal lugs from the generator terminal studs.
 (e)  Install the nuts (17) and washers (19) on the generator terminal studs.
 (f) (g)  Tighten the nuts (17) with your hand.Install the terminal block cover (16) on the generator (2 or 11).
 S 424-095
 (8)  Install caps on all electrical connectors.
 S 024-096
 (9)  To remove the air exhaust duct (3) from APU generator, G3 (2), do these steps: (a) Remove the screws (23), washers (22) and nuts (21) from the clamp (24). (b) Remove the nut (27) and spacer (26) from the air exhaust duct clamp. (c) Remove the air exhaust duct (3).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-21-03
 ALL  ú ú 03 Page 406 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 1(86)