* SEE THE WDM EQUIPMENT LIST
AC Generation - Component Index
Figure 101 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-20-00
ALL ú
ú 05 Page 101
ú Oct 10/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 FAULT ISOLATION/MAINT MANUAL
COMPONENT FIG. 102 SHT QTY ACCESS/AREA REFERENCE
CIRCUIT BREAKERS 1 117AL, MAIN EQUIP CTR, P514,P515,
P614,P615
LIGHTNING PROTECTOR GEN 1A, C8013 1 *
LIGHTNING PROTECTOR GEN 1B, C8014 1 *
LIGHTNING PROTECTOR GEN 1C, C8015 1 *
LIGHTNING PROTECTOR GEN 2A, C8019 1 *
LIGHTNING PROTECTOR GEN 2B, C8020 1 *
LIGHTNING PROTECTOR GEN 2C, C8021 1 *
LIGHTNING PROTECTOR GEN 3A, C8026 1 *
LIGHTNING PROTECTOR GEN 3B, C8025 1 *
LIGHTNING PROTECTOR GEN 3C, C8024 1 *
LIGHTNING PROTECTOR GEN 4A, C8016 1 *
LIGHTNING PROTECTOR GEN 4B, C8017 1 *
LIGHTNING PROTECTOR GEN 4C, C8018 1 *
CIRCUIT BREAKER 1 117AL, MAIN EQUIP CTR, P714,P715
AUX POWER BREAKER 1, C955 1 24-22-02
AUX POWER BREAKER 2, C956 1 24-22-02
GENERATOR - APU 1, G2 6 1 317AL,318AR, APU ACCESS DOOR 24-21-03
GENERATOR - APU 2, G3 6 1 317AL,318AR, APU ACCESS DOOR 24-21-03
INVERTER - APU STATIC, M8128 1 1 835L, AFT EQUIP CTR, E33 RACK 24-29-04
INVERTER - MAIN STATIC, M7438 1 1 117AL, MAIN EQUIP CTR, E30 RACK 24-29-01
MODULE - ELEC SYSTEM CONT, M7307 1 1 FLT COMPT, P5 24-22-01
APU STANDBY BUS XFER, R7853 RELAYS - (REF 31-01-42,-45, FIG. 101) APU INVERTER XFER, R1434 AUX PWR BRKR CLOSE PROT #1, R301 AUX PWR BRKR CLOSE PROT #2, R7050 EXT PWR CONT 1, R12 EXT PWR CONT 2, R13 GND SERVICE TRANSFER, R15 GND SERVICE SELECT, R14 MODULE - GEN FIELD MAN RESET, M7322 1 1 FLT COMPT, P461 24-22-06
RELAY - STANDBY POWER TRANSFER, R7227 1 1 FLT COMPT, P6 24-29-03
RING - APU GENERATOR QUICK ATTACH-DETACH 6 1 317AL,318AR, APU ACCESS DOOR 24-21-02
UNIT - AUX GEN 1 CONT, G26 1 1 117AL, MAIN EQUIP CTR, E1 RACK 24-23-05
UNIT - AUX GEN 2 CONT, G27 1 1 117AL, MAIN EQUIP CTR, E2 RACK 24-23-05
UNIT - BUS 1 CONT, G10 1 1 117AL, MAIN EQUIP CTR, E1 RACK 24-23-01
UNIT - BUS 2 CONT, G11 1 1 117AL, MAIN EQUIP CTR, E2 RACK 24-23-01
UNIT - GEN 1 CONT, G6 1 1 117AL, MAIN EQUIP CTR, E1 RACK 24-23-01
UNIT - GEN 2 CONT, G7 1 1 117AL, MAIN EQUIP CTR, E1 RACK 24-23-01
UNIT - GEN 3 CONT, G8 1 1 117AL, MAIN EQUIP CTR, E2 RACK 24-23-01
UNIT - GEN 4 CONT, G9 1 1 117AL, MAIN EQUIP CTR, E2 RACK 24-23-01
AC Generation - Component Index
Figure 101 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-20-00
ALL ú ú 03 Page 102 ú Jun 10/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
FAULT ISOLATION/MAINT MANUAL
GENERATOR FIELD MANUAL
RESET MODULE, M7322
SEE B
P461 PANEL
P5 PANEL P515 PANEL
ELECTRICAL SEE E SHT 2
SYSTEM P615 PANEL
CONTROL
P92 PANEL MODULE, SEE F SHT 3 P415 PANEL
M7307 SEE A
P715 PANEL
SEE H SHT 3 ELECTRICAL AND P6 PANEL
ELECTRONICS RACK P180 PANEL
SEE C SHT 2 SEE I SHT 4
P514 PANEL
FLIGHT COMPARTMENT
SEE D SHT 2
P614 PANEL P714 PANEL SEE D SHT 2 SEE G SHT 3
P414 PANEL EQUIPMENT RACK SEE M SHT 5 E30
MAIN EQUIPMENT CENTER
ELECTRICAL SYSTEM CONTROL GENERATOR FIELD MANUAL MODULE, M7307 RESET MODULE, M7322 (EXAMPLE)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 1(74)