 NOTE: The change from external power to IDG power must not
____ cause an interruption in the power service that you can see.
 S 215-057
 (27)
 Make sure that these EICAS messages do not show on the main EICAS screen:

 (a)
ELEC GEN OFF 1

 (b)
ELEC GEN OFF 2

 (c)
ELEC GEN OFF 3

 (d)
ELEC GEN OFF 4


 S 215-029
 (28)
 Make sure that the EICAS synoptic page shows:

 (a)
The generator circuit breakers 1, 2, 3, and 4 are closed.

 (b)
The bus tie breakers 1, 2, 3, and 4 are closed.

 (c)
The split system breaker is closed.


 S 865-039
 (29) Apply airplane loads to the ac and dc buses.
 NOTE: Airplane loads include galley ovens, window heat,
____
 compartment heat, and water heaters.

 S 715-040
 (30)
 Get access to the electrical maintenance page through the CMC (AMM 45-10-00/201).

 S 215-060

 (31)
 Make sure that the IDG 1, 2, 3, and 4 show these values:

 (a)
115 | 5 volts ac

 (b)
400 | 5 Hz frequency

 (c)
The IDGs show equal loads.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-20-00
 ALL  ú ú 03 Page 509 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 S 215-041
 (32)
 Make sure that the AVAIL lights on APU GEN 1 and APU GEN 2 switches are on.

 S 715-042

 (33)
 Push the APU GEN 1 and APU GEN 2 switches to ON.

 S 215-043

 (34)
 Make sure that the ON lights on APU GEN 1 and APU GEN 2 switches come on in 4 seconds.


 NOTE: The change from IDG power to APU power must not cause an
____
 interruption in the power service that you can see.

 S 215-044
 (35)
 Make sure that the OFF lights on GEN CONT 1, 2, 3, and 4 switches are on.

 S 215-045

 (36)
 Make sure that the electrical maintenance page for the APU generators 1 and 2 show:

 (a)
115 | 5 volts ac

 (b)
400 | 5Hz frequency

 (c)
The two APU generators show an electrical load.


 S 865-046
 (37)
 Remove the airplane loads from the ac and dc buses.

 S 215-050

 (38)
 Make sure that the AVAIL lights on EXT PWR 1 and EXT PWR 2 switches are on.

 S 715-051

 (39)
 Push the EXT PWR 1 and EXT PWR 2 switches to ON.

 S 215-063

 (40)
 Make sure that the ON lights on the EXT PWR 1 and 2 switches come on in 4 seconds.


 NOTE: The change from APU power to external power must not
____ cause an interruption in the power service that you can see.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-20-00
 ALL  ú ú 04 Page 510 ú Feb 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 215-052
 (41)
 Make sure that the AVAIL lights on APU GEN 1 and APU GEN 2 are on.

 (a)  
Make sure that the ON lights are off.

 E.
Put the Airplane back to the Usual Condition.


 S 865-053
 (1)  
Stop the engines (AMM 71-00-00/201).

 S 865-054

 (2)  
Stop the APU (AMM 49-11-00/201).

 S 865-055

 (3)  
Remove the electrical power from the airplane, if it is not necessary (AMM 24-22-00/201).


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-20-00
 ALL  ú ú 02 Page 511 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 1.
2.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 1(79)