24-11-01
ALL ú ú 02 Page 210 ú Jun 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
(2) S 792-062Spray the talcum powder or foot powder over the IDG and the IDG external cooling circuit.
(3) S 792-054Dry motor the engine for one minute (AMM 71-00-00/201).
(4) S 212-053Check for oil leaks from the IDG or IDG external cooling circuit.
NOTE:____ Oil leaks will show as streaks in the talcum powder.
(a) If the oil leaks are found, repair or replace the components as needed.
(5) S 612-060Service the IDG (AMM 12-22-07/301).
(6) S 712-055Do the engine ground test - idle power procedure to do a check for leaks (AMM 71-00-00/501).
(7) S 212-056Examine the IDG oil level (AMM 12-13-07/301).
(8) S 612-061Service the IDG (AMM 12-13-07/301).
(9) S 412-059Close the left thrust reverser half (AMM 78-31-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-11-01
ALL ú ú 02 Page 211 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
INTEGRATED DRIVE GENERATOR - REMOVAL/INSTALLATION
_________________________________________________
1. General
_______
A. This procedure contains two tasks:
(1)
The removal of the integrated drive generator G19 (IDG)
(2)
The installation of the integrated drive generator G19 (IDG).
B.
The IDG is found on the aft face of the main gearbox, at the
6 o'clock position.
C.
Get access to the IDG through the left thrust reverser half.
TASK 24-11-01-004-052
2. Integrated Drive Generator Removal (Fig. 401)
__________________________________
A. Special Tools and Equipment
(1) A71015-67 - Lift Fixture - Engine Accessory (Hoist) (Recommended) A71015-66 - Lift Fixture - Engine Accessory (Hoist) (Alternative)
Hien Werner Model 62 (Alternative)
Licoln B67554 or W93720 (Alternative)
(2) A71013-82 Hoist Adapter - Integrated Drive Generator (Used with A71015 Lifting Fixture) (Recommended)
The following tools used with Hein Warner Model 62 or Licoln B67554 or W93720 jacks: (Alternative)
Combination of:
A71013-19 Spacer Assembly
A71013-40 Spacer Assembly
A71013-45 Spacer Assembly
A71015-82 Hoist Adapter Assembly
B. Standard Tools and Equipment
(1)
Container - 5 U.S. gallon (20 liter) capacity, suitable to collect oil drainage from IDG
(2)
Adapter - Outlet, OMP2505-3, Ozone Metal Products, 101-32 101st Street, Ozone Park, Long Island, NY 11416
(3)
Hose - to connect to outlet adapter
(4)
Overflow drain tool, Risbridger 2315, W & J Risbridger Ltd. Bletchingley, NR. Redhill, Surrey RH1 4LN, England (optional)
C.
References
(1)
AIPC 24-11-01, Fig. 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-11-01
ALL ú ú 01P Page 401 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
POWER FEEDER CABLES
SEE E
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 1(27)