(a)
Remove all metal burrs with a file.
S 016-002
S 216-004
(3) Examine the QAD ring, the adapter plate, and the tension bolt for damage.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-21-02
ALL ú ú 03 Page 601 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
SEE A
FWD
SEE B
A
QAD RING
ADAPTER PLATE
APU LOAD GEARBOX
QAD RING
QAD RING
TENSION BOLT ____NOTE: QAD RING REMOVED FOR CLARITY.
B
APU-Driven Generator Quick Attach-Detach (QAD) Ring Inspection
Figure 601A
D21028
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-21-02
ALL ú ú 06 Page 602 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 216-005
(4)
Examine the inner surface of the QAD ring along the clamp track area.
(a)
Replace the QAD ring if the worn areas are not equal around the ring.
S 416-006
(5) Install the APU-driven generator (AMM 24-21-03/401).
TASK 24-21-02-206-007
3. APU-Driven Generator Quick Attach-Detach (QAD) Ring Tension Bolt Torque Check_____________________________________________________________________________ (Fig. 602)
A. Standard Tools and Equipment
(1)
Mallet - Soft (rubber, fiber, or equivalent)
B.
References
(1)
AIPC 49-51-02 Fig. 1
C.
Access
(1)
Location Zone
317 APU Compartment, LH
318 APU Compartment, RH
(2)
Access Panel
317AL APU Access Door
318AR APU Access Door
D.
Procedure
(1)
Open the latches on the APU access doors.
(2)
Open the APU access doors (317AL, 318AR).
(3)
Install the door support rods.
S 226-009
(4)
Do a check of the torque on the tension bolt.
(a)
Measure the torque of the tension bolt.
S 016-019
S 016-015
S 016-016
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-21-02
ALL ú ú 03 Page 603 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
SEE A
AIR EXHAUST
DUCT
FWD
SEE B
A
QUICK ATTACH-
DETACH APU-DRIVEN
(QAD) RING GENERATOR
TENSION
BOLT
FEELER
GAGE
GAP
NOTE: AIR EXHAUST DUCT REMOVED
B
FOR CLARITY.
APU-Driven Generator Quick Attach-Detach (QAD) Ring
Tension Bolt Torque Check
Figure 602A
D21010
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-21-02
ALL ú ú 04 Page 604 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(b) Make sure the torque is 120-130 pound-inches.
1) If the torque is less than 120 pound-inches, do these steps: a) Tighten the tension bolt to 120-130 pound-inches. b) Hit the QAD ring lightly with a soft mallet. c) Measure the bolt torque. d) If the torque is less than 120 pound-inches, tighten
the bolt to 120-130 pound-inches. e) Do steps B) through D) until the measured torque does not decrease. f) Tighten the bolt to 120-130 pound-inches.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 1(84)