24-11-00
ALL ú ú 01 Page 102 ú Dec 10/88
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
FAULT ISOLATION/MAINT MANUAL
RIGHT THRUST SEE F
REVERSER HALF 416 (ENG 1)
426 (ENG 2) INTERMEDIATE 436 (ENG 3) CASE (REF) 446 (ENG 4)
SEE D
FWD
SEE EIDG AIR/OIL HEAT EXCHANGER
IDG AIR/OIL HEAT EXCHANGER VALVE, V350 D
E
INTERMEDIATE CASE (REF)
FWD
IDG AIR/OIL HEAT EXCHANGER VALVE OVERRIDE PRESSURE SWITCH, S1611
F
Generator Drive System - Component Location Figure 102 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-11-00
ALL ú ú 03 Page 103 ú Feb 10/89
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
GENERATOR DRIVE SYSTEM - MAINTENANCE PROCEDURES
_______________________________________________
1. General_______
A. This procedures contains two tasks.
B. The first task is the procedure to release the pressure from the
integrated drive generator (IDG) oil system.
(1)
You must release pressure from the IDG oil system before you do maintenance on the system components.
(2)
Open the service access door, for the IDG, on the left core cowl panel.
C.
The second task is the procedure to do a static leak check of the IDG oil system.
(1)
It will be necessary to fill the IDG oil system frequently, if there is a leak in the system.
(2)
The static leak check applies compressed air or nitrogen to the IDG oil system through the IDG pressure fill fitting. Then you monitor the gas pressure to find out if the system has a leak.
(3)
Get access to the IDG oil system through the thrust reverser halves.
TASK 24-11-00-862-001
2. Release the Pressure from the IDG Oil System____________________________________________
A. Standard Tools and Equipment
(1)
Adapter - Outlet, OMP2505-3, Ozone Metal Products, 101-32 101th Street, Ozone Park, Long Island, NY 11416
(2)
Hose - To connect to outlet adapter
(3)
Container - 5 U.S. gallon (20 liter) capacity, suitable to collect oil drainage from IDG
B.
References
(1)
AIPC 24-11-01, Fig. 1
(2)
AIPC 24-11-01, Fig. 2
C.
Access
(1)
Location Zone 412 Engine 1 - Main Gearbox Aft Face 7 o'clock 422 Engine 2 - Main Gearbox Aft Face 7 o'clock 432 Engine 3 - Main Gearbox Aft Face 7 o'clock 442 Engine 4 - Main Gearbox Aft face 7 o'clock
(2)
Access Panel
417B IDG Service Pressure Relief Access Door
427B IDG Service Pressure Relief Access Door
437B IDG Service Pressure Relief Access Door
447B IDG Service Pressure Relief Access Door
D.
Procedure
S 012-002
(1)
Open the service access door, for the IDG, on the left core cowl panel.
(2)
Remove the cover from the overflow drain coupling on the IDG.
S 032-004
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-11-00
ALL ú ú 01 Page 201 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
SEE B
SEE A
OIL SUPPLY TO EXTERNAL OIL CIRCUIT IDG (619) GEARBOX MAIN FWD ECSEE (IDG) (G19) DRIVE GENERATOR INTEGRATED
A
OIL RETURN FROM EXTERNAL OIL CIRCUIT
COUPLING PRESSURE FILL
CONTAINER OVERFLOW DRAIN COUPLING WITH TUBE
B
Figure 201 Integrated Drive Generator Depressurization
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 1(17)