Location Zone 412 Engine 1 - Main Gearbox Aft Face 7 o'clock 422 Engine 2 - Main Gearbox Aft Face 7 o'clock 432 Engine 3 - Main Gearbox Aft Face 7 o'clock 442 Engine 4 - Main Gearbox Aft Face 7 o'clock 221 Control Cabin, LH

 (2)  
Access Panel
 415 Left Thrust Reverser Half - Engine 1
 425 Left Thrust Reverser Half - Engine 2
 435 Left Thrust Reverser Half - Engine 3
 445 Left Thrust Reverser Half - Engine 4


 D.  
Prepare for the Test

 (1)  
Supply external electrical power (AMM 24-22-00/201).

 (2)  
Test the indicator lights for the electrical system.


 S 865-002
 S 715-003
 NOTE: The lights are found on the P5 overhead panel and the
____
 P461 overhead maintenance panel.

 (a)  
Set the IND LTS switch to TEST.

 (b)  
Make sure that all the indicator lights for the electrical system are on.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-11-00
 ALL  ú ú 02 Page 501 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

SEE A
SEE B
FLIGHT COMPARTMENT
ELECTRICAL
1  2  3  4 
EXT 1  APU 1  APU 2  EXT 2 
AC-V  0  115  115  115  115  115  0  115 
FREQ  0  400  400  400  400  400  0  400 
LOAD  0.00  0.73  0.75  0.75  0.75  0.75  0.00  0.65 
MAIN BAT  APU BAT 
DC-V  28  28  28  28  28  28 
DC-A  CHG10  35  35  35  35  DIS10 

IDG OUT.TEMP 145 175 145 145 IDG RISE TEMP 35 35 35 35
GEN 2 DRIVE DATE02SEP90 GMT18:54:04
ELECTRICAL SYSTEM CONTROL MODULE ELECTRICAL SYSTEM MAINTENANCE DISPLAY (TYPICAL)
B A
Electrical System Control/Maintenance Display Location Figure 501
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-11-00
 ALL  ú ú 01 Page 502 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
 (c)  Set the IND LTS switch to BRT.
 (3)  S 865-006Make sure that the L and R UTILITY switches are ON. (a) Make sure that the OFF lights are not on.
 (4)  S 865-008Set the BUS TIE 1, 2, 3, and 4 switches to AUTO. (a) Make sure that the ISLN lights are off. 

SEE A
MAIN GEARBOX
INTEGRATED DRIVE GENERATOR
FWD IDG RESET RING
A
Integrated Drive Generator Reset Ring Location
Figure 502

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-11-00
 ALL  ú ú 02 Page 503 ú Feb 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 865-007
 (5)  
Make sure that the GEN CONT 1, 2, 3, and 4 switches are ON.

 (a)  
Make sure that the OFF lights are on.


 S 865-042
 (6)  
Make sure that the DRIVE lights on the DRIVE DISC 1, 2, 3, and 4 switches are ON.

 S 865-009

 (7)  
Make sure that the FIELD OFF lights on the manual field reset switches, are off.


 NOTE: The manual field reset switches are for the IDG generators.
____
 (a)  
The FIELD OFF lights are found on the P461 overhead maintenance panel.

 (b)  
If the FIELD OFF light(s) are on, push and release the field reset switch to turn the lights off.


 E. Do the Operational Test
 S 615-011
 (1)  Fill the IDG oil if it is necessary (AMM 12-13-07/301).
 NOTE: If the IDG oil reservoir is empty, the overtemperature relief
____
 valve on the IDG possibly opened.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 1(20)