(2)
WDM 21-23-22
(3)
SSM 21-23-02
B. Access
(1) Location Zone
124 Forward Cargo Compartment Aft Half, RH
C. Procedure
S 864-002
(1) Open these circuit breakers and attach DO-NOT CLOSE tags:
(a)
P6 Main Power Distribution Panel
1) 6E34 CARGO AIR COND PCA
(b)
P180 DC Power Distribution Panel 1) 180E28 FWD CARGO VLV PWR EXH BACK UP
S 034-003
(2) Remove the electrical connector DV531 from the valve.
NOTE: The valve is in the floor area of the forward cargo
____
compartment at station 770.
S 034-004
(3)
Remove the bonding jumper from the valve.
S 034-005
(4)
Loosen the clamp on the inboard end of the valve and remove the inlet assembly.
S 024-006
(5)
Loosen the clamp on the outboard end of the valve and remove the valve.
S 034-007
(6)
Install a cover on the duct opening to prevent entry of unwanted objects.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-26-18
ALL ú ú 03 Page 401 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
SEE A
STA 770
LOWER FORWARD
LOWER FORWARD CARGO
CARGO OVERBOARD
OVERBOARD VALVE
BACKUP VALVE
(REF) INLET SCREEN
CLAMP (2 LOCATIONS)
LOWER FORWARD CARGO OVERBOARD
EXHAUST STACK
A
Lower Forward Cargo Overboard Backup Valve - Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-26-18
ALL ú ú 03 Page 402 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
TASK 21-26-18-404-008
3. Valve Installation
__________________
A. References
(1)
AMM 21-26-00/501, Ventilation System
(2)
24-22-00/201, Manual Control
(3)
IPC 21-58-51 Fig. 10
(4)
WDM 21-23-22
(5)
SSM 21-23-02
B. Access
(1) Location Zone
124 Forward Cargo Compartment Aft Half, RH
C. Procedure
S 434-009
(1)
Remove the cover from the duct opening.
S 214-010
(2)
Make sure the mating surfaces of the valve and duct are clean.
S 424-011
(3)
Install the valve with the flow arrow pointed to the overboard valve and install the clamp on the inboard end of the valve.
S 434-012
(4)
Put the inlet assembly on the outboard end of the fan and install the clamp.
S 214-013
(5)
Examine the valve installation to make sure the clamps are tight and the valve aligns correctly with the duct.
S 434-014
(6)
Install the bonding jumper on the valve.
S 434-015
(7)
Install the electrical connector DV531 on the valve.
S 864-016
(8)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a)
P6 Main Power Distribution Panel
1) 6E34 CARGO AIR COND PCA
(b)
P180 DC Power Distribution Panel 1) 180E28 FWD CARGO VLV PWR EXH BACK UP
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 1(74)