(b)
Overhead Circuit Breaker Panel, P180 1) 180E11, CARGO VENT AFT CONT
S 014-034
(3) Remove the sidewall lining from the area immediately forward of the flapper valve screen in the aft left corner of the bulk cargo compartment (AMM 25-55-02/401).
D. Remove the Fan
S 034-035
(1)
Remove the electrical connector, DB8291, from the fan.
(2)
Remove the clamps from each end of the fan.
(3)
Pull the flex duct from the forward end of the fan.
S 034-036
S 034-037
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-26-08
ALL ú ú 01F Page 401 ú Oct 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
BOLT, WASHERS, NUT (2 LOCATIONS)
INLET SCREEN/CHECK VALVE ASSEMBLYBULK CARGO FAN
SEE A
FAN
ELECTRICAL CONNECTOR CLAMP (2 LOCATIONS)
SLEEVE
BOLT, WASHERS, NUT (2 LOCATIONS)
BULK CARGO FAN
A
Bulk Cargo Fan - Installation
Figure 401
FWD
INBD
C77171
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-26-08
ALL ú ú 01F Page 402 ú Oct 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 034-060
(4)
Pull the rubber sleeve and the inlet screen/check valve assembly from the aft end of the fan.
S 034-038
(5)
Remove the nuts, bolts, and washers from the lug at the top of the fan.
S 034-039
(6)
Remove the nuts, bolts, and washers from the lug at the bottom of the fan.
S 014-040
(7)
Remove the fan.
S 434-041
(8)
Put a cover over the duct opening.
TASK 21-26-08-404-043
3. Bulk Cargo Fan Installation (Fig. 401)___________________________
A. References
(1)
AMM 24-22-00/201, Manual Control
(2)
AMM 25-55-02/401, Bulk Compartment Ceiling and Sidewall Lining
(3)
IPC 21-40-51 Fig. 1
(4)
WDM 21-27-22
(5)
SSM 21-27-03
B. Access
(1) Location Zone
145 Bulk Cargo Compartment, LH
C. Install the Fan
S 034-043
(1) Remove the cover from the duct opening.
(a) Make sure there is no unwanted material in the duct.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-26-08
ALL ú ú 01F Page 403 ú Oct 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 984-044
(2)
Hold the fan in position with the flow arrow pointed forward and install the bolts, nuts and washers on the lug at the bottom of the fan.
S 434-045
(3)
Install the nuts, bolts, and washers on the lug at the top of the fan.
S 434-046
(4)
Install the inlet screen/check valve assembly with the sleeve on the aft end of the fan.
S 434-047
(5)
Pull the flex duct onto the forward end of the fan.
S 434-048
(6)
Install the clamps on both ends of the fan.
S 434-049
(7)
Install the electrical connector, DB8291, onto the fan.
S 864-050
(8)
Remove the DO-NOT-CLOSE identifiers and close these circuit
breakers:
(a)
Right Power Distribution Center, P415
1) 415H38, VENT FAN PWR BULK CARGO
(b)
Overhead Circuit Breaker Panel, P180
1) 180E11, CARGO VENT AFT CONT
中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 1(63)