21-43-00
ALL ú ú 03 Page 1 ú Feb 10/89
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
BSEE HEATERS COMPARTMENT FORWARD CARGO HEAT COMPARTMENT FORWARD CARGO
SEE A SEE C COOLING EXHAUST EQUIPMENT BYPASS DUCT COOLING EQUIPMENT EXHAUST GROUND COOLING EQUIPMENT A VALVE (REF) EXHAUST INBOARD
HEATER
BOX SENSOR
SENSOR TEMPERATURE
B
COVERPLATE TEMPERATURE
SWITCH
TEMPERATURE SENSOR ASSEMBLY
C
Forward Cargo Compartment Heating System Equipment LocationFigure 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-43-00
ALL ú ú 01 Page 2 ú Oct 10/88
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
28V DC BUS 2
HEATER CURRENT SENSOR (P414)
Forward Cargo Compartment Heating System Schematic Figure 2
C76633
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-43-00
ALL ú ú 16 Page 3 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
(2)
For the heaters to operate the forward cargo air conditioning system must be off , the equipment cooling inboard exhaust valve must be open, and at least two engines must be at greater than 50% power. When compartment temperature falls to 40°F (4°C) the temperature switch closes and the heaters energize. The system supplies heat until compartment temperature increases to 50°F (10°C). At this time, the temperature switch opens, removing power to the heaters.
(3)
If the heaters are on when the equipment cooling inboard exhaust valve closes, the inboard exhaust valve control relay will de-energize and cause the heater control relay to de-energize. This removes power to the heaters. The inboard exhaust valve will close in the equipment cooling automatic bypass (fan failure) mode or the override mode (Ref 21-58-00).