• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-06 23:15来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (1)  
The removal of power to the heater

 (2)  
Get access to the heater

 (3)  
The removal of the heater

 (4)  
The installation of the heater

 (5)  
An operational test of the heater.


 TASK 21-42-02-004-001
 2.  Flight Crew Shoulder Heater Removal (Fig. 401)
___________________________________
 A.  References
 (1)  
AMM 24-22-00/201, Manual Control

 (2)  
AMM 25-19-04/401, Flight Deck Crew Rest Lining

 (3)  
AMM 25-40-03/401, Upper Deck Lavatories

 (4)  
AIPC 21-22-51 Fig. 1

 (5)  
SSM 21-45-05

 (6)  
WDM 21-45-31


 B.  Access
 (1)  Location Zone
 221 Control Cabin, LH
 222 Control Cabin, RH

 C.  Prepare for the Removal
 NOTE: The flight crew shoulder heaters are installed at floor level,
____ immediately inboard of the fuselage, at Station 390 [20 inches (50 cm) aft of the escape hatch centerline].
 S 014-029
 (1)  For the captain's shoulder heater, remove the flight compartment crew rest sidewall lining to get access to the heater (AMM 25-19-04/401).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-42-02
 ALL  ú ú 05 Page 401 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL


(2 LOCATIONS)
LEFT HEATER (EXAMPLE)

Flight Crew Shoulder Heater Installation
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-42-02
 ALL  ú ú 01 Page 402 ú Oct 10/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 014-035
 (2)  For the first officer's shoulder heater, remove the forward right upper deck lavatory (AMM 25-40-03/401).
 D. Heater Removal
 S 864-024
 (1)  For the captain's shoulder heater, open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  P414 Power Distribution Center - Left 1) 414H10 AUX HEAT PWR CAPT HIGH 2) 414H11 AUX HEAT PWR CAPT LOW
 S 864-025
 (2) For the first officer's heater, open these circuit breakers
 (a)  P414 Power Distribution Center - Left. 1) 414H12 AUX HEAT PWR F/O HIGH 2) 414H13 AUX HEAT PWR F/O LOW
 S 034-026
 (3)  Remove the electrical connector from the heater:
 (a)  
The captain's shoulder heater electrical connector DH523

 (b)  
The first officer's shoulder heater electrical connector DH524.


 S 034-027
 (4)  
Loosen the clamps at each end of the heater and pull the ducts from the heater.

 S 024-028

 (5)  
Remove the support clamps and remove the heater.


 TASK 21-42-02-404-008
 3. Flight Crew Shoulder Heater Installation
________________________________________
 A. References
 (1)  AMM 21-00-00/201, Air Conditioning
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-42-02
 ALL  ú ú 18 Page 403 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (2)  
AMM 24-22-00/201, Manual Control

 (3)  
AMM 25-19-04/401, Flight Deck Crew Rest Lining

 (4)  
AMM 25-28-01/201, Overhead Stowage Bins

 (5)  
AMM 25-40-03/401, Upper Deck Lavatories

 (6)  
AMM 32-09-02/201, Air/Ground Relay System

 (7)  
AMM 35-11-18/401, Mask/Regulator/Stowage Box

 (8)  
AIPC 21-22-51 Fig. 1

 (9)  
SSM 21-45-05

 (10)
 WDM 21-45-31


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 1(143)