 NOTE: The maximum permitted clearance between the motor mounting
____ flange and the actuator body is 0.060 inch (1.5 mm).
 S 434-013
 (6)  Install the electrical connector on the AC motor:
 (a)  
The AC motor electrical connector for the left valve - DV91A

 (b)  
The AC motor electrical connector for the right valve - DV90A.


 S 414-023
 (7)  
Install the safety screen.

 S 864-014

 (8)  
Remove the DO-NOT-CLOSE tags and close these circuit breakers:


 (a)  P6 Main Power Distribution Panel 1) 6J28 CABIN PRESS AUTO A 2) 6J29 CABIN PRESS AUTO B 3) 6J30 CABIN PRESS CONT L ICU 4) 6J31 CABIN PRESS CONT R ICU 5) 6L6 CABIN PRESS MAN L
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-31-06
 ALL  ú ú 01 Page 404 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 6) 6L7 CABIN PRESS MAN R
 (b)  
P414 Power Distribution Center-Left
 1) 414M8 CABIN PRESS ICU LEFT
 2) 414B8 CABIN PRESS ICU RIGHT


 (c)  
P83 in aft equipment center
 1) OUTFLOW VALVE-R
 2) OUTFLOW VALVE-L

 

 S 864-015
 (9)  Apply electrical power (AMM 24-22-00/201).
 S 744-022
 CAUTION: MAKE SURE THERE IS NO BLOCKAGE IN THE VALVE FLAPPER DOORS.
_______ THE AUTOMATIC MOVEMENT OF THE VALVES DURING THE GROUND TEST CAN CAUSE DAMAGE IF THE VALVE FLAPPER DOORS ARE NOT FREE TO MOVE.
 (10) Do a ground test of the cabin pressure control system (CPCS) on the CMC CDU (AMM 21-31-00/501):
 (a) Make sure the AUTO SELECT switch is set to the NORM position.
 NOTE: The AUTO SELECT switch is on the P5 overhead panel.
____
 (b)  Make sure the MAN L and MAN R switches are set to off.
 NOTE: The MAN L and MAN R switches are on the P5 overhead
____
 panel.

 (c)  
Select <GROUND TESTS from the CMC main menu.

 (d)  
Select <21 CABIN PRESSURE from the ground tests menu.

 (e)  
Select <CPCS-A or <CPCS-B from the cabin pressure menu.

 (f)  
Make sure that IN PROGRESS shows on the CMC CDU.

 (g)  
Make sure that PASS shows on the CMC CDU.


 S 864-021
 (11) Remove electrical power (AMM 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-31-06
 ALL  ú ú 01 Page 405 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 PRESSURIZATION OUTFLOW VALVE ACTUATOR ASSEMBLY - REMOVAL/INSTALLATION
_____________________________________________________________________
 1.  General_______
 A.  There are two tasks in this procedure. There is one task for the removal and one task for the installation of an outflow valve actuator assembly. The procedure has these parts:
 (1)  
The removal of power to the valve

 (2)  
The removal of the access panel from the aft bulkhead of the bulk cargo compartment

 (3)  
The removal of the outflow valve actuator

 (4)  
The installation of the outflow valve actuator

 (5)  
A test of the outflow valve.


 B.  The removal and installation procedure is the same for the left and the right outflow valve actuator.
 TASK 21-31-07-004-001
 2.  Pressurization Outflow Valve Actuator Removal (Fig. 401)_____________________________________________
 A.  References
 (1)  
24-22-00/201, Manual Control

 (2)  
IPC 21-31-01 Fig. 1

 (3)  
WDM 21-31-13, 21-31-21, 21-31-22

 (4)  
SSM 21-31-02, 21-31-04


 B.  Access
 (1)  Location Zone
 151 Area Aft of Bulk Cargo Compartment, LH
 152 Area Aft of Bulk Cargo Compartment, RH

 C.  Procedure
 S 864-002
 (1)  Open these circuit breakers and attach DO-NOT-CLOSE tags:
 