EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-44-02
ALL ú ú 10 Page 404 ú Oct 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
(b) If the temperature of the air in the aft cargo compartment is more than 40°F (5°C), do this step: 1) Apply a cool source to the probe end of the low temperature
switch.
NOTE: This will decrease the temperature of the switch
____
to less than 40°F (5°C).
(c) If the temperature of the air in the aft cargo compartment is more than 80°F (25°C), do this step: 1) Apply a cool source to the overheat switch.
NOTE: This will decrease the temperature of the switch
____ to less than 80°F (25°C).
(d) Do a check for air flow from the holes in the heat ducts found in the aft cargo compartment.
S 034-018
(11)
Remove the cool source from the sensor assembly.
S 434-019
(12)
Install the coverplate to the temperature sensor assembly with the screws.
S 864-020
(13)
Put the AFT CARGO HT switch on the P5 overhead panel in the OFF position.
S 864-021
(14)
Remove the pneumatic pressure if it is not necessary (Ref 36-00-00/201).
S 864-022
(15)
Remove the electrical power if it is not necessary (Ref 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-44-02
ALL ú ú 02 Page 405 ú Oct 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
AFT CARGO OVERHEAT SWITCH - REMOVAL/INSTALLATION
________________________________________________
1. General_______
A. This procedure has two tasks. The first task is for the removal of the overheat switch for the aft cargo compartment. The other task is for the installation of the overheat switch.
B. The overheat switch is in the bulk cargo compartment on the left sidewall. The overheat switch is in a sensor box which contains the temperature sensor assembly for the cargo compartment.
C. The procedure has these steps:
-
Remove power from the overheat switch
-
Remove the coverplate from the sensor box
-
Remove the overheat switch
-Install the overheat switch
-Do a test of the overheat switch.
TASK 21-44-04-004-001
2. Aft Cargo Overheat Switch Removal (Fig. 401)_________________________________
A. References
(1)
AIPC 21-43-03 Fig. 1
(2)
WDM 21-44-11, WDM 21-44-12
(3)
SSM 21-44-01
B. Access
(1) Location Zone
145 Bulk Cargo Compartment, LH
C. Procedure
S 864-002
(1) Open this circuit breaker on the P7 overhead circuit breaker panel and attach a DO-NOT-CLOSE tag:
(a) 7H9, CARGO HEAT AFT
S 014-003
(2) Find the sensor box on the left sidewall (STA 2010) in the bulk cargo compartment.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-44-04
ALL ú ú 02 Page 401 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
SENSOR BOX SEE A TEMPERATURE SENSOR (REF) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 1(164)